On December 26, 2020, Lake County Fire Protection District responded to a fire incident at 2991 6th St, Clearlake, CA 95422, a 1-or-2 family dwelling.

The alarm was received at 10:25 AM, 1 suppression and 1 other personnel arrived at 10:30 AM, and the last unit was cleared at 10:41 AM. The time to arrive was 5 minutes and the total incident time was 16 minutes.

The following action was taken during the incident: investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 2991 6th St, Clearlake, CA 95422
County Lake County
State CA
City Clearlake
Zip Code 95422
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 16 minutes

Response


Incident Type Building fires
Department Station 70
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 1
EMS Personnel 0
Other Personnel 1

Fire Department


Name Lake County Fire Protection District
Department Type Mostly volunteer
Address 14815 Olympic Dr
Clearlake, CA 95422-9522
Phone (707) 994-2170

Actions Taken


First Action Taken Investigate fire out on arrival

Metadata


Incident Key CA_17005_12262020_021500_0
State California
Fire Department ID 17005
Incident Date 12/26/2020
Incident Number 021500
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Electrical Dist

Ignition


Area of Origin Bedroom - < 5 persons; included are jail or prison
Heat Source Arcing
Item First Ignited Interior wall covering excluding drapes, etc
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Short circuit arc from defective, worn insulation

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Building Length 40 ft
Building Width 20 ft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Undetermined

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary