On August 25, 2021, City of Greer Fire Department responded to a fire incident at 302 Bailey Rd, Greer, SC 29651, a 1-or-2 family dwelling.
The alarm was received at 6:03 PM, 12 suppression and 2 other personnel arrived at 6:09 PM, the incident was controlled at 6:16 PM, and the last unit was cleared at 9:33 PM. The time to arrive was 6 minutes, the time to control the incident was 7 minutes, and the total incident time was 3 hours, 30 minutes.
The following actions were taken during the incident: extinguish, search, and salvage and overhaul.
Sponsored
Location
| Type | Street address |
| Address | 302 Bailey Rd, Greer, SC 29651 |
| County | Greenville County |
| State | SC |
| City | Greer |
| Zip Code | 29651 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 6 minutes
Incident controlled at
Alarm to incident controlled: 7 minutes
Last unit cleared at
Alarm to last unit cleared: 3 hours, 30 minutes
Response
| Incident Type | Building fires |
| Department Station | 41 |
| Mutual Aid Given/Received | Automatic aid received |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 12 |
| EMS Personnel | 0 |
| Other Personnel | 2 |
Fire Department
| Name | City of Greer Fire Department |
| Department Type | Career |
| Address | 103 W Poinsett St Greer, SC 29650-1940 |
| Phone | (864) 848-2166 |
| Website | http://www.cityofgreer.org/163/About-Us |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Search |
| Third Action Taken | Salvage & overhaul |
Losses *
| Property Loss | $40,000 |
| Contents Loss | $3,000 |
| Property Value | $120,000 |
| Contents Value | $10,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | SC_23313_08252021_2664_0 |
| State | South Carolina |
| Fire Department ID | 23313 |
| Incident Date | 08/25/2021 |
| Incident Number | 2664 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Electrical Dist |
Ignition
| Area of Origin | Attic: vacant, crawl space above top story, cupola |
| Heat Source | Arcing |
| Item First Ignited | Structural member or framing |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Electrical failure, malfunction, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Structural member or framing |
| Type Material Contributing Most To Spread | Sawn wood, including all finished lumber |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1152 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 1 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Stationary |