On December 23, 2022, Ligonier Fire Department responded to a fire incident at 304 S Martin St, Ligonier, IN 46767, a 1-or-2 family dwelling.

The alarm was received at 2:00 PM, 4 suppression and 6 other personnel arrived at 2:09 PM, the incident was controlled at 2:46 PM, and the last unit was cleared at 3:42 PM. The time to arrive was 9 minutes, the time to control the incident was 37 minutes, and the total incident time was 1 hour, 42 minutes.

The following actions were taken during the incident: incident command, extinguish, and investigate.

Sponsored

Location


Type Street address
Address 304 S Martin St, Ligonier, IN 46767
County Noble County
State IN
City Ligonier
Zip Code 46767
Property Use 1 or 2 family dwelling
Census Tract Ligoni

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 9 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 37 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 42 minutes

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received Mutual aid received
Resources Include Mutual Aid Yes
Shift B
Alarms 1
District 1

Personnel


Support Personnel 4
EMS Personnel 0
Other Personnel 6

Fire Department


Name Ligonier Fire Department
Department Type Mostly volunteer
Address 100 N Cavin St
Ligonier, IN 46767
Phone (260) 894-3124

Actions Taken


First Action Taken Incident command
Second Action Taken Extinguish
Third Action Taken Investigate

Losses *


Property Loss $10,000
Contents Loss $5,000
Property Value $89,000
Contents Value $30,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key IN_57005_12232022_22689_0
State Indiana
Fire Department ID 57005
Incident Date 12/23/2022
Incident Number 22689
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Unclassified elec malfunction

Ignition


Area of Origin Attic: vacant, crawl space above top story, cupola
Heat Source Arcing
Item First Ignited Undetermined
Type of Material Undetermined
Cause of Ignition Unintentional
Factor Contributing To Ignition Electrical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 1
Total Square Feet 1850 sqft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present