Summary
On November 27, 2012, McCausland Volunteer Fire Department, Inc. responded to a fire incident at 31075 210 Ave, Mccausland, IA 52758, an outbuilding/shed.
The alarm was received at 9:00 PM, 8 suppression and 2 other personnel arrived at 9:11 PM, the incident was controlled at 9:11 PM, and the last unit was cleared at 10:04 PM. The time to arrive was 11 minutes and the total incident time was 1 hour, 4 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Type | Street address |
| Address | 31075 210 Ave, Mccausland, IA 52758 |
| County | Scott County |
| State | IA |
| City | McCausland |
| Zip Code | 52758 |
| Property Use | Outbuilding or shed |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 11 minutes
Incident controlled at
Last unit cleared at
Alarm to last unit cleared: 1 hour, 4 minutes
Response
| Incident Type | Building fires |
| Department Station | 1 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 8 |
| EMS Personnel | 0 |
| Other Personnel | 2 |
Fire Department
| Name | McCausland Volunteer Fire Department, Inc. |
| Department Type | Volunteer |
| Address | 305 N Salina St PO Box 207 McCausland, IA 52758-0207 |
| Phone | (563) 225-6464 |
Actions Taken
| First Action Taken | Extinguish |
Losses *
| Property Loss | $500 |
| Contents Loss | $500 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | IA_82010_11272012_12-069_0 |
| State | Iowa |
| Fire Department ID | 82010 |
| Incident Date | 11/27/2012 |
| Incident Number | 12-069 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Electrical Dist |
Ignition
| Area of Origin | Wall assembly |
| Heat Source | Arcing |
| Item First Ignited | Insulation within structural area |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
On-Site Materials
| On-Site Material | Pets |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1200 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Stationary |