Report Icon

Incident Report – 06/22/1989
315 Polar St, Avoca, NE 68307

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On June 22, 1989, Avoca Rural Fire Department #5 responded to a fire incident at 315 Polar St, Avoca, NE 68307, a residential use, 1-or-2 family dwelling.

The alarm was received at 11:50 AM and 24 suppression personnel arrived at 11:55 AM. The time to arrive was 5 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 315 Polar St, Avoca, NE 68307
County Cass County
State NE
City Avoca
Zip Code 68307
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector alerted occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received Mutual aid received
Shift 0
Alarms 1
District 000

Personnel


Support Personnel 24
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Avoca Rural Fire Department #5
Department Type Volunteer
Address 211 Polar
Avoca, NE 68307
Phone (402) 275-3345

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key NE_20002_062289_400089_00
State Nebraska
Fire Department ID 20002
Incident Date 06/22/1989
Incident Number 400089
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Cooking

Legacy Fields


Mutual Aid Yes
Estimated Dollar Loss 10,000
Day of Week Thursday
Time In Service 14:00
Zip Code 68307
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Exterior wall surface
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 2
Equipment Involved in Ignition Open fired grill
Form of Heat of Ignition Spark, ember, flame escaping from liquid fueled equipment
Type of Material Ignited Sawn wood
Form of Material Ignited Exterior sidewall covering, surface, finish
Ignition Factor Part failure, leak, break
Construction Type Protected Wood Frame
Extent of Flame Damage Confined to structure of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Exterior sidewall covering, surface, finish
Detector Performance Detector(s) in the room or space of fire origin, and they operated
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Sawn wood
Avenue of Smoke Travel Stairwell
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 10,000-24,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Spark, ember or flame from operating equipment
Item First Ignited Exterior wall covering or finish
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Leak or break

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 76

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Operation Operated
Detector Effectiveness Undetermined

Mobile Property Involved


Mobile Property Type Aerial tramway vehicle

Equipment


Equipment Power Liquid fuel, other
Equipment Portability Portable
Sponsored