Incident Report – 12/06/2018 32407 Huber Ln, Fraser, MI 48026
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On December 6, 2018, Fraser Department of Public Safety responded to a fire incident at 32407 Huber Ln, Fraser, MI 48026, a 1-or-2 family dwelling.
The alarm was received at 5:28 PM, 5 suppression and 3 other personnel arrived at 5:32 PM, the incident was controlled at 5:44 PM, and the last unit was cleared at 6:08 PM. The time to arrive was 4 minutes, the time to control the incident was 12 minutes, and the total incident time was 40 minutes.
The following actions were taken during the incident: incident command, assistance/other, and ventilate.
Sponsored
Location
| Type | Street address |
| Address | 32407 Huber Ln, Fraser, MI 48026 |
| County | Macomb County |
| State | MI |
| City | Fraser |
| Zip Code | 48026 |
| Property Use | 1 or 2 family dwelling |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 4 minutes
Incident controlled at
Alarm to incident controlled: 12 minutes
Last unit cleared at
Alarm to last unit cleared: 40 minutes
Response
| Incident Type | Building fires |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | 3 |
| Alarms | 1 |
Personnel
| Support Personnel | 5 |
| EMS Personnel | 0 |
| Other Personnel | 3 |
Fire Department
| Name | Fraser Department of Public Safety |
| Department Type | Mostly career |
| Address | 33000 Garfield Rd Fraser, MI 48026-1858 |
| Phone | (586) 293-2000 |
| Website | https://www.micityoffraser.com/ |
Actions Taken
| First Action Taken | Incident command |
| Second Action Taken | Assistance, other |
| Third Action Taken | Ventilate |
Losses *
| Property Loss | $1,000 |
| Contents Loss | $500 |
| Property Value | $150,000 |
| Contents Value | $500 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | MI_05007_12062018_1756-18_0 |
| State | Michigan |
| Fire Department ID | 05007 |
| Incident Date | 12/06/2018 |
| Incident Number | 1756-18 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Unclassified elec malfunction |
Ignition
| Area of Origin | Laundry area, wash house (laundry) |
| Heat Source | Arcing |
| Item First Ignited | Item First Ignited, Other |
| Type of Material | Plastic |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Electrical failure, malfunction, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Liquids, piping, filters, other |
| Type Material Contributing Most To Spread | Plastic |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 1 |
| Total Square Feet | 1000 sqft |
Number of Stories With Damage
| Story of Fire Origin | -1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Undetermined |
Sponsored