Report Icon

Incident Report – 12/29/2022
338 Burncoat St, Worcester, MA 01606

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 29, 2022, Worcester Fire Department responded to a fire incident at 338 Burncoat St, Worcester, MA 01606, a residential use, 1-or-2 family dwelling.

The alarm was received at 5:27 AM, 6 suppression personnel arrived at 5:32 AM, and the last unit was cleared at 7:04 AM. The time to arrive was 5 minutes and the total incident time was 1 hour, 37 minutes.

The following action was taken during the incident: investigate.

Sponsored

Location


Type Street address
Address 338 Burncoat St, Worcester, MA 01606
County Worcester County
State MA
City Worcester
Zip Code 01606
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 300
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 37 minutes

Response


Incident Type Building fires
Department Station zzz
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift 1
Alarms 21

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 0

Fire Department


Name Worcester Fire Department
Department Type Career
Address 141 Grove St
Worcester, MA 01605-1707
Phone (508) 799-1818
Website https://www.worcesterma.gov/fire

Actions Taken


First Action Taken Investigate

Losses *


Property Loss $10
Contents Loss $490
Property Value $325,000
Contents Value $10,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key MA_27348_12292022_2243885_0
State Massachusetts
Fire Department ID 27348
Incident Date 12/29/2022
Incident Number 2243885
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Flame, Heat
Main Fire Cause Smoking

Ignition


Area of Origin Bedroom - < 5 persons; included are jail or prison
Heat Source Cigarette
Item First Ignited Bedding; blanket, sheet, comforter
Type of Material Fabric, fiber, cotton, blends, rayon, wool
Cause of Ignition Unintentional
Factor Contributing To Ignition Heat source too close to combustibles
Factor Contributing To Ignition Abandoned or discarded materials or products

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Bedding; blanket, sheet, comforter
Type Material Contributing Most To Spread Fabric, fiber, cotton, blends, rayon, wool

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 0
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 1
Building Length 24 ft
Building Width 32 ft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Human Factors Contributing to Ignition


Human Factor Asleep

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type More than 1 type present
Detector Power Battery Only
Detector Operation Fire too small to operate
Sponsored