Incident Report – 09/15/2022 36 Prospect St, Everett, MA 02149
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On September 15, 2022, Everett Fire Department responded to a fire incident at 36 Prospect St, Everett, MA 02149, a non-mixed use, residential street/road or residential driveway.
The alarm was received at 8:06 PM, 13 suppression personnel arrived at 8:09 PM, and the last unit was cleared at 8:35 PM. The time to arrive was 3 minutes and the total incident time was 29 minutes.
The following actions were taken during the incident: investigate and refer to proper authority.
Sponsored
Location
| Type | Street address |
| Address | 36 Prospect St, Everett, MA 02149 |
| County | Middlesex County |
| State | MA |
| City | EVERETT |
| Zip Code | 02149 |
| Mixed Use | Not mixed use |
| Property Use | Residential street, road or residential driveway |
| Census Tract | 342500 |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 3 minutes
Last unit cleared at
Alarm to last unit cleared: 29 minutes
Response
| Incident Type | Fires in structures other than in a building |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | C |
| Alarms | 01 |
| District | 2 |
Personnel
| Support Personnel | 13 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Everett Fire Department |
| Department Type | Career |
| Address | 384 Broadway Everett, MA 02149-3427 |
| Phone | (617) 394-2348 |
| Website | https://everettfirema.com/ |
Actions Taken
| First Action Taken | Investigate |
| Second Action Taken | Refer to proper authority |
Metadata
| Incident Key | MA_17093_09152022_148219_0 |
| State | Massachusetts |
| Fire Department ID | 17093 |
| Incident Date | 09/15/2022 |
| Incident Number | 148219 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Unclassified elec malfunction |
Ignition
| Area of Origin | Highway, parking lot, street: on or near |
| Heat Source | Arcing |
| Item First Ignited | Electrical wire, cable insulation |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Undetermined |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Short circuit arc from defective, worn insulation |
Spread
| No Flame Spread/Same As First/Unknown | No |
Structure
| Not Residential | No |
| Number of Residential Units | 0 |
| Number of Buildings Involved | 0 |
| Structure Type | Structure type, other |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 0 |
| Building Height: Stories Below Grade | 0 |
| Building Length | 40 ft |
| Building Width | 25 ft |
Number of Stories With Damage
| Story of Fire Origin | 0 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |