Incident Report – 07/20/1998 39458 150th St, Springbrook, IA 52075
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On July 20, 1998, Springbrook Fire & EMS responded to a fire incident at 39458 150th St, Springbrook, IA 52075, a farm use, livestock/poultry storage area.
The alarm was received at 1:40 PM and 6 suppression personnel arrived at 1:50 PM. The time to arrive was 10 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 39458 150th St, Springbrook, IA 52075 |
| County | Jackson County |
| State | IA |
| City | Springbrook |
| Zip Code | 52075 |
| Mixed Use | Farm use |
| Property Use | Livestock, poultry storage |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 10 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 1 |
| Alarms | 1 |
Personnel
| Support Personnel | 6 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Springbrook Fire & EMS |
| Department Type | Volunteer |
| Address | 101 S 1st PO Box 3 Springbrook, IA 52075 |
| Phone | (563) 872-4941 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | IA_49014_072098_199113_00 |
| State | Iowa |
| Fire Department ID | 49014 |
| Incident Date | 07/20/1998 |
| Incident Number | 199113 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Estimated Dollar Loss | 1,000 |
| Day of Week | Monday |
| Time In Service | 14:30 |
| Zip Code | 52075 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Farm complex |
| Fixed Property Use | Barns, stables |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Exterior wall surface |
| Level of Fire Origin | 10 to 19 feet above grade |
| Number of Stories | 2 |
| Equipment Involved in Ignition | Fixed wiring |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Hardboard, plywood |
| Form of Material Ignited | Exterior sidewall covering, surface, finish |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Protected ordinary |
| Extent of Flame Damage | Confined to room of origin |
| Extent of Smoke Damage | Confined to the object of origin |
| Form of Material Generating Most Smoke | Type of Material not applicable |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Avenue of Smoke Travel | No significant avenue of smoke travel |
| Method of Extinguishment | Preconnected hose line(s) with water from hydrant, draft, standpipe |
| Property Damage Classification | 1,000-9,999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | STORAGE PROPERTY: UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Exterior wall covering or finish |
| Type of Material | Plywood |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
Number of Stories With Damage
| Story of Fire Origin | 76 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Aerial tramway vehicle |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |
Sponsored