Summary
On April 21, 2016, Cumberland Fire District responded to a fire incident at 4 Sandy Way, Cumberland, RI 02864, a 1-or-2 family dwelling.
The alarm was received at 6:16 PM, 14 suppression and 3 other personnel arrived at 6:23 PM, the incident was controlled at 7:20 PM, and the last unit was cleared at 9:46 PM. The time to arrive was 7 minutes, the time to control the incident was 57 minutes, and the total incident time was 3 hours, 30 minutes.
The following actions were taken during the incident: extinguish, search, and ventilate.
Sponsored
Location
| Type | Street address |
| Address | 4 Sandy Way, Cumberland, RI 02864 |
| County | Providence County |
| State | RI |
| City | CUMBERLAND |
| Zip Code | 02864 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 7 minutes
Incident controlled at
Alarm to incident controlled: 57 minutes
Last unit cleared at
Alarm to last unit cleared: 3 hours, 30 minutes
Response
| Incident Type | Building fires |
| Department Station | 4 |
| Mutual Aid Given/Received | Mutual aid received |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 14 |
| EMS Personnel | 0 |
| Other Personnel | 3 |
Fire Department
| Name | Cumberland Fire District |
| Department Type | Career |
| Address | 3502 Mendon Rd Cumberland, RI 02864-2136 |
| Phone | (401) 658-0544 |
| Website | http://cumberlandfire.org/ |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Search |
| Third Action Taken | Ventilate |
Losses *
| Property Loss | $100,000 |
| Contents Loss | $15,000 |
| Property Value | $400,000 |
| Contents Value | $30,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | RI_00802_04212016_1407_0 |
| State | Rhode Island |
| Fire Department ID | 00802 |
| Incident Date | 04/21/2016 |
| Incident Number | 1407 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Ignition
| Area of Origin | Structural area, other |
| Heat Source | Heat from powered equipment, other |
| Item First Ignited | Electrical wire, cable insulation |
| Type of Material | Hay, straw |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Heat source too close to combustibles |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Structural component or finish, other |
| Type Material Contributing Most To Spread | Wood chips, sawdust, shavings |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 1 |
| Building Length | 40 ft |
| Building Width | 26 ft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 1 |
| Number of Stories with Damage: Heavy | 2 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Operation | Undetermined |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Portable |