Incident Report – 01/19/2022 40 Payson Ave, Boston, MA 02125
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On January 19, 2022, Boston Fire Department responded to a fire incident at 40 Payson Ave, Boston, MA 02125, a multifamily dwelling.
The alarm was received at 11:00 PM, personnel arrived at 11:03 PM, and the last unit was cleared at 11:30 PM. The time to arrive was 3 minutes and the total incident time was 30 minutes.
The following actions were taken during the incident: extinguish, incident command, and ventilate.
Sponsored
Location
| Type | Street address |
| Address | 40 Payson Ave, Boston, MA 02125 |
| County | Suffolk County |
| State | MA |
| City | BOSTON |
| Zip Code | 02125 |
| Property Use | Multifamily dwellings |
| Detector Alerted Occupants | Detector alerted occupants |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 3 minutes
Last unit cleared at
Alarm to last unit cleared: 30 minutes
Response
| Incident Type | Building fires |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | 2 |
| Alarms | 1 |
| District | 07 |
Fire Department
| Name | Boston Fire Department |
| Department Type | Career |
| Address | 115 Southampton St Boston, MA 02118-2713 |
| Phone | (617) 343-3710 |
| Website | https://www.cityofboston.gov/fire/ |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Incident command |
| Third Action Taken | Ventilate |
Losses *
| Property Loss | $3,000 |
| Contents Loss | $2,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | MA_25035_01192022_0004207_0 |
| State | Massachusetts |
| Fire Department ID | 25035 |
| Incident Date | 01/19/2022 |
| Incident Number | 0004207 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Flame, Heat |
| Main Fire Cause | Open Flame |
| Priority Cause | Matches, Candles |
Ignition
| Area of Origin | Bedroom - < 5 persons; included are jail or prison |
| Heat Source | Candle |
| Item First Ignited | Soft goods, wearing apparel, other |
| Type of Material | Fabric, fiber, cotton, blends, rayon, wool |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Heat source too close to combustibles |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 4 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 1 |
| Total Square Feet | 1200 sqft |
Number of Stories With Damage
| Story of Fire Origin | 2 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Hardwire with battery |
| Detector Operation | Operated |
| Detector Effectiveness | Alerted Occupants |