Incident Report – 08/06/2021 403 Unity St, Bloomer, WI 54724
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On August 6, 2021, Bloomer Fire Department responded to a fire incident at 403 Unity St, Bloomer, WI 54724, a residential property.
The alarm was received at 12:01 AM, 21 suppression and 2 EMS personnel arrived at 12:08 AM, the incident was controlled at 12:20 AM, and the last unit was cleared at 2:12 AM. The time to arrive was 7 minutes, the time to control the incident was 12 minutes, and the total incident time was 11 minutes.
The following actions were taken during the incident: extinguish and salvage and overhaul.
Sponsored
Location
| Type | Street address |
| Address | 403 Unity St, Bloomer, WI 54724 |
| County | Chippewa County |
| State | WI |
| City | Bloomer |
| Zip Code | 54724 |
| Property Use | Residential, other |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 7 minutes
Incident controlled at
Alarm to incident controlled: 12 minutes
Last unit cleared at
Alarm to last unit cleared: 11 minutes
Response
| Incident Type | Building fires |
| Mutual Aid Given/Received | Mutual aid received |
Personnel
| Support Personnel | 21 |
| EMS Personnel | 2 |
| Other Personnel | 0 |
Fire Department
| Name | Bloomer Fire Department |
| Department Type | Volunteer |
| Address | 1631 Oak St Bloomer, WI 54724 |
| Phone | (715) 568-5817 |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Salvage & overhaul |
Losses *
| Property Loss | $100,000 |
| Contents Loss | $25,000 |
| Property Value | $217,300 |
| Contents Value | $50,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | WI_09010_08062021_0806211_0 |
| State | Wisconsin |
| Fire Department ID | 09010 |
| Incident Date | 08/06/2021 |
| Incident Number | 0806211 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Natural |
| Main Fire Cause | Natural |
Ignition
| Area of Origin | Ceiling & floor assembly, crawl space b/t stories |
| Heat Source | Lightning |
| Item First Ignited | Structural member or framing |
| Type of Material | Natural gas |
| Cause of Ignition | Unintentional |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Flammable liquid/gas in container or pipe |
| Type Material Contributing Most To Spread | Natural gas |
Structure
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 1 |
| Building Length | 60 ft |
| Building Width | 50 ft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Heavy | 2 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Undetermined |
Sponsored