Report Icon

Incident Report – 10/10/1991
405 E 3rd St, Wellston, OH 45692

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On October 10, 1991, Wellston Fire Department responded to a fire incident at 405 E 3rd St, Wellston, OH 45692, a residential use, 1-or-2 family dwelling.

The alarm was received at 6:49 AM and 5 suppression personnel arrived at 6:52 AM. The time to arrive was 3 minutes.

The following action was taken during the incident: investigate.

Sponsored

Location


Address 405 E 3rd St, Wellston, OH 45692
County Jackson County
State OH
City Wellston
Zip Code 45692
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 000000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 3 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 3
Alarms 1
District 003

Personnel


Support Personnel 5
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Wellston Fire Department
Department Type Mostly volunteer
Address 200 N Pennsylvania Ave
Wellston, OH 45692
Phone (740) 384-2128
Website https://wellstonfd.net/

Actions Taken


First Action Taken Investigate

Metadata


Incident Key OH_40009_101091_000167_00
State Ohio
Fire Department ID 40009
Incident Date 10/10/1991
Incident Number 000167
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Heating

Legacy Fields


Estimated Dollar Loss 200
Day of Week Thursday
Zip Code 45692
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Investigation only
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Heating equipment room or area, water heater area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 2
Equipment Involved in Ignition Central heating unit
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Type of Material not classified above
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage Confined to structure or origin
Form of Material Generating Most Smoke Electrical wire, cable insulation
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Type of Material not classified above
Avenue of Smoke Travel Air handling duct
Method of Extinguishment Self-extinguished
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Type of material first ignited, other
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Unspecified short-circuit arc

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 62

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown
Sponsored