On March 9, 2018, Leander Fire Department responded to a fire incident at 407 Apache Trl, Leander, TX 78641, a 1-or-2 family dwelling.

The alarm was received at 8:53 PM, 9 suppression and 1 other personnel arrived at 9:00 PM, and the last unit was cleared at 9:27 PM. The time to arrive was 7 minutes and the total incident time was 34 minutes.

The following action was taken during the incident: investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 407 Apache Trl, Leander, TX 78641
County Williamson County
State TX
City Leander
Zip Code 78641
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 7 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 34 minutes

Response


Incident Type Building fires
Department Station 3
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 9
EMS Personnel 0
Other Personnel 1

Fire Department


Name Leander Fire Department
Department Type Mostly career
Address 101 E Sonny Dr
Leander, TX 78641
Phone (512) 528-2848
Website https://www.leandertx.gov/fire

Actions Taken


First Action Taken Investigate fire out on arrival

Metadata


Incident Key TX_XV308_03092018_643_0
State Texas
Fire Department ID XV308
Incident Date 03/09/2018
Incident Number 643
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Cooking area, kitchen
Heat Source Heat from powered equipment, other
Item First Ignited Multiple items first ignited
Type of Material Fiberboard, particleboard, and hardboard
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Electrical failure, malfunction, other
Factor Contributing To Ignition Heat source too close to combustibles

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Cabinetry (including built-in)
Type Material Contributing Most To Spread Fiberboard, particleboard, and hardboard

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1300 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Undetermined

Equipment


Equipment Brand Fridgidare
Equipment Model LFEF3018TB
Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary