Incident Report – 09/02/2020 4141 Laurel Valley Dr, Powell, OH 43065
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On September 2, 2020, Liberty Township Fire Department responded to a fire incident at 4141 Laurel Valley Dr, Powell, OH 43065, a 1-or-2 family dwelling.
The alarm was received at 8:09 PM, 10 suppression, 2 EMS, and 1 other personnel arrived at 8:14 PM, the incident was controlled at 8:18 PM, and the last unit was cleared at 8:59 PM. The time to arrive was 5 minutes, the time to control the incident was 4 minutes, and the total incident time was 50 minutes.
The following action was taken during the incident: fire/other.
Sponsored
Location
| Type | Street address |
| Address | 4141 Laurel Valley Dr, Powell, OH 43065 |
| County | Delaware County |
| State | OH |
| City | Powell |
| Zip Code | 43065 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 5 minutes
Incident controlled at
Alarm to incident controlled: 4 minutes
Last unit cleared at
Alarm to last unit cleared: 50 minutes
Response
| Incident Type | Building fires |
| Department Station | 322 |
| Mutual Aid Given/Received | Automatic aid received |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 10 |
| EMS Personnel | 2 |
| Other Personnel | 1 |
Fire Department
| Name | Liberty Township Fire Department |
| Department Type | Mostly career |
| Address | 7761 Liberty RD N Powell, OH 43065-8998 |
| Phone | (740) 938-2021 |
| Website | http://www.libertytwp.org/ |
Actions Taken
| First Action Taken | Fire, other |
Losses *
| Property Loss | $12,000 |
| Contents Loss | $500 |
| Property Value | $329,400 |
| Contents Value | $100,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | OH_21117_09022020_1646_0 |
| State | Ohio |
| Fire Department ID | 21117 |
| Incident Date | 09/02/2020 |
| Incident Number | 1646 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Flame, Heat |
| Main Fire Cause | Other Heat |
| Priority Cause | Other open flame, spark |
Ignition
| Area of Origin | Wall assembly |
| Heat Source | Flame/torch used for lighting |
| Item First Ignited | Exterior wall covering or finish |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Plywood |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Misuse of material or product, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 4 |
| Building Height: Stories Below Grade | 1 |
| Total Square Feet | 3248 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Hardwire with battery |
| Detector Operation | Fire too small to operate |