Report Icon

Incident Report – 08/06/2015
4265 Pershing Dr, Beaumont, TX 77705

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On August 6, 2015, Beaumont Fire/ Rescue Services responded to a fire incident at 4265 Pershing Dr, Beaumont, TX 77705, a 1-or-2 family dwelling.

The alarm was received at 1:01 AM, 19 suppression personnel arrived at 1:05 AM, and the last unit was cleared at 3:07 AM. The time to arrive was 4 minutes and the total incident time was 6 minutes.

The following actions were taken during the incident: extinguish, salvage and overhaul, and action taken/other.

As a result of the incident, there was 1 fire service injury.

Sponsored

Location


Type Street address
Address 4265 Pershing Dr, Beaumont, TX 77705
County Jefferson County
State TX
City Beaumont
Zip Code 77705
Property Use 1 or 2 family dwelling
Census Tract 002500
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 6 minutes

Response


Incident Type Building fires
Department Station 003
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift A
Alarms 1
District C51

Personnel


Support Personnel 19
EMS Personnel 0
Other Personnel 0

Fire Department


Name Beaumont Fire/ Rescue Services
Department Type Career
Address 400 Walnut St
Beaumont, TX 77701
Phone (409) 880-3901
Website https://fire.beaumonttexas.gov/

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul
Third Action Taken Action taken, other

Injuries/Deaths


Fire Service Injuries 1
Fire Service Deaths 0

Losses *


Property Loss $5,500
Contents Loss $2,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key TX_NH701_08062015_1510451_0
State Texas
Fire Department ID NH701
Incident Date 08/06/2015
Incident Number 1510451
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Cooking area, kitchen
Heat Source Arcing
Item First Ignited Undetermined
Cause of Ignition Unintentional
Factor Contributing To Ignition Short circuit arc from mechanical damage

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Structural member or framing
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1900 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 1
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Undetermined

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary

Firefighter Casualty Report

Injured Person


Gender Male
Age 31
Career Career

Injury Date and Time


Injury Date and Time 08/06/2015 2:15 AM

Physical Condition


Physical Condition Rested

Severity


Severity Lost time injury, moderate severity

Taken To


Taken To Hospital

Activity At Time Of Injury


Activity At Time of Injury Overhaul

Injury


Primary Apparent Symptom Dehydration
Where Injury Occurred At scene, in structure
Injury Relation to Structure Inside/On Structure
Story of Injury 1
Protective Equipment Contributed to Injury No