Report Icon

Incident Report – 09/27/2018
43 Delta Drive, Tchula, MS 39169

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On September 27, 2018, Tchula Volunteer Fire Department responded to a fire incident at 43 Delta Drive, Tchula, MS 39169, a 1-or-2 family dwelling.

The alarm was received at 1:45 PM, 6 suppression personnel arrived at 1:55 PM, and the last unit was cleared at 3:45 PM. The time to arrive was 10 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 43 Delta Drive, Tchula, MS 39169
County Holmes County
State MS
City Tchula
Zip Code 39169
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector alerted occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 10 minutes

  • Last Unit Cleared

    Last unit cleared at

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 0

Fire Department


Name Tchula Volunteer Fire Department
Department Type Volunteer
Address 403 Front St
PO Box 356
Tchula, MS 39169-0356
Phone (662) 235-5112

Actions Taken


First Action Taken Extinguish

Losses *


Property Loss $80,000
Contents Loss $8,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key MS_26007_09272018_0000050_0
State Mississippi
Fire Department ID 26007
Incident Date 09/27/2018
Incident Number 0000050
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Bedroom - < 5 persons; included are jail or prison
Heat Source Spark, ember or flame from operating equipment
Item First Ignited Electrical wire, cable insulation
Type of Material Undetermined
Cause of Ignition Unintentional
Factor Contributing To Ignition Short circuit arc from defective, worn insulation

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 0
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1300 sqft

Number of Stories With Damage


Story of Fire Origin 1

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Undetermined

Mobile Property Involved


Mobile Property State Mississippi