Incident Report – 12/01/1993 437 N 8th Ave, Canton, IL 61520
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On December 1, 1993, Canton Fire Department responded to a fire incident at 437 N 8th Ave, Canton, IL 61520, a residential use, 1-or-2 family dwelling.
The alarm was received at 1:24 AM and 4 suppression personnel arrived at 1:29 AM. The time to arrive was 5 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 437 N 8th Ave, Canton, IL 61520 |
| County | Fulton County |
| State | IL |
| City | Canton |
| Zip Code | 61520 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Census Tract | 000000 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 5 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 1 |
| Alarms | 1 |
| District | 001 |
Personnel
| Support Personnel | 4 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Canton Fire Department |
| Department Type | Career |
| Address | 101 E Spruce St Canton, IL 61520-1946 |
| Phone | (309) 647-0040 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | IL_FD172_120193_930763_00 |
| State | Illinois |
| Fire Department ID | FD172 |
| Incident Date | 12/01/1993 |
| Incident Number | 930763 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Appliances |
Legacy Fields
| Estimated Dollar Loss | 2,000 |
| Day of Week | Wednesday |
| Time In Service | 21:40 |
| Zip Code | 61520 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Area of Fire Origin | Crawl space, substructure space |
| Level of Fire Origin | Below ground level or water level |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Dryer |
| Form of Heat of Ignition | Heat from gas fueled equipment |
| Type of Material Ignited | Cotton, rayon, cotton fabric, finished goods |
| Form of Material Ignited | Cleaning supplies |
| Ignition Factor | Mechanical Failure, Malfunction; insufficient information available to classify further |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to the object of origin |
| Extent of Smoke Damage | Confined to structure or origin |
| Form of Material Generating Most Smoke | Cleaning supplies |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Cotton, rayon, cotton fabric, finished goods |
| Avenue of Smoke Travel | Stairwell |
| Method of Extinguishment | Preconnected hose line(s) with water carried in apparatus tanks |
| Property Damage Classification | 1,000-9,999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
Fire Report
Ignition
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Household utensils |
| Type of Material | Fabric, fiber, cotton, blends, rayon, wool |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Mechanical failure, malfunction, other |
Structure
| Number of Residential Units | 1 |
Number of Stories With Damage
| Story of Fire Origin | 71 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Home, garden vehicle |
Equipment
| Equipment Power | Gas fuels, other |
| Equipment Portability | Unknown |
Hazmat Report
Cause of Release
| Cause of Release | Container or containment failure |
Equipment Involved in Release
Equipment
| Equipment Brand | MAYTAG |
| Equipment Model | NA |
| Equipment Serial Number | NA |
Legacy Fields
| Type of Situation Found | Structure fire |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Area of Fire Origin | Crawl space, substructure space |
| Equipment Involved in Ignition | Dryer |
| Form of Heat of Ignition | Heat from gas fueled equipment |
| Type of Material Ignited | Cotton, rayon, cotton fabric, finished goods |
| Form of Material Ignited | Cleaning supplies |
| Ignition Factor | Mechanical Failure, Malfunction; insufficient information available to classify further |
| Dollar Loss | $2,000 |
Mobile Property
Description
| Model | NA |
| License Plate | NA |
Legacy Fields
| Make | NA |
| Serial Number | NA |
| Type of Situation Found | Structure fire |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Area of Fire Origin | Crawl space, substructure space |
| Equipment Involved in Ignition | Dryer |
| Form of Heat of Ignition | Heat from gas fueled equipment |
| Type of Material Ignited | Cotton, rayon, cotton fabric, finished goods |
| Form of Material Ignited | Cleaning supplies |
| Ignition Factor | Mechanical Failure, Malfunction; insufficient information available to classify further |
| Time of Arrival | 1:24 |
| Dollar Loss | $2,000 |
Sponsored