On October 21, 2022, Pine Bluff Fire & Emergency Services responded to a fire incident at 4403 W Short 4th Ave, Pine Bluff, AR 71602, a residential property.
The alarm was received at 12:49 AM, 9 suppression and 1 other personnel arrived at 12:55 AM, and the last unit was cleared at 1:37 AM. The time to arrive was 6 minutes and the total incident time was 48 minutes.
The following actions were taken during the incident: fire/other and information/investigation and enforcement/other.
Sponsored
Location
| Type | Street address |
| Address | 4403 W Short 4th Ave, Pine Bluff, AR 71602 |
| County | Jefferson County |
| State | AR |
| City | Pine Bluff |
| Zip Code | 71602 |
| Property Use | Residential, other |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 6 minutes
Last unit cleared at
Alarm to last unit cleared: 48 minutes
Response
| Incident Type | Building fires |
| Department Station | ST6 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 9 |
| EMS Personnel | 0 |
| Other Personnel | 1 |
Fire Department
| Name | Pine Bluff Fire & Emergency Services |
| Department Type | Career |
| Address | 200 E 8TH Ave Pine Bluff, AR 71601-5006 |
| Phone | (870) 730-2048 |
Actions Taken
| First Action Taken | Fire, other |
| Second Action Taken | Information, investigation & enforcement, other |
Losses *
| Property Loss | $0 |
| Contents Loss | $200 |
| Property Value | $0 |
| Contents Value | $200 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | AR_35600_10212022_4663_0 |
| State | Arkansas |
| Fire Department ID | 35600 |
| Incident Date | 10/21/2022 |
| Incident Number | 4663 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Heating |
| Priority Cause | Heating |
Ignition
| Area of Origin | Bathroom, checkroom, lavatory, locker room |
| Heat Source | Heat from powered equipment, other |
| Item First Ignited | Electrical wire, cable insulation |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Equipment overloaded |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1500 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Battery Only |
| Detector Operation | Failed to Operate |
| Detector Failure Reason | Defective |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Stationary |
Sponsored