Report Icon

Incident Report – 03/11/2013
4906 Wheatridge Rd, Fort Wayne, IN 46835

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On March 11, 2013, Fort Wayne Fire Department responded to a fire incident at 4906 Wheatridge Rd, Fort Wayne, IN 46835, a 1-or-2 family dwelling.

The alarm was received at 2:29 PM, 14 suppression personnel arrived at 2:35 PM, and the last unit was cleared at 3:25 PM. The time to arrive was 6 minutes and the total incident time was 56 minutes.

The following actions were taken during the incident: extinguish, salvage and overhaul, and information/investigation and enforcement/other.

Sponsored

Location


Type Street address
Address 4906 Wheatridge Rd, Fort Wayne, IN 46835
County Allen County
State IN
City FORT WAYNE
Zip Code 46835
Property Use 1 or 2 family dwelling

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 56 minutes

Response


Incident Type Building fires
Department Station 04
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift B
Alarms 1
District S04

Personnel


Support Personnel 14
EMS Personnel 0
Other Personnel 0

Fire Department


Name Fort Wayne Fire Department
Department Type Career
Address 1 E Main ST, STE 901
Fort Wayne, IN 46802-1830
Phone (260) 427-1170
Website https://www.fortwaynefiredepartment.org/

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul
Third Action Taken Information, investigation & enforcement, other

Metadata


Incident Key IN_02005_03112013_0006780_0
State Indiana
Fire Department ID 02005
Incident Date 03/11/2013
Incident Number 0006780
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Attic: vacant, crawl space above top story, cupola
Heat Source Arcing
Item First Ignited Undetermined
Type of Material Undetermined
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Short circuit arc from defective, worn insulation

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 1
Total Square Feet 1800 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored