Incident Report – 09/05/1980
500 W Main St, Payson, AZ 85541

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On September 5, 1980, a fire department near Payson, AZ responded to a fire incident at 500 W Main St, Payson, AZ 85541, a business and residential use, motor vehicle/boat sales/services/repair.

The alarm was received at 7:14 PM and 18 suppression personnel arrived at 12:00 AM. The time to arrive was 19 hours, 14 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 500 W Main St, Payson, AZ 85541
County Gila County
State AZ
City Payson
Zip Code 85541
Mixed Use Business and residential use
Property Use Motor vehicle or boat sales, services, repair
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 19 hours, 14 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 1
Alarms 1

Personnel


Support Personnel 18
EMS Personnel Unknown
Other Personnel Unknown

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key AZ_04180_090580_026380_00
State Arizona
Fire Department ID 04180
Incident Date 09/05/1980
Incident Number 026380
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Unclassified elec malfunction

Legacy Fields


Estimated Dollar Loss 100
Day of Week Friday
Time In Service 20:31
Zip Code 85541
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Business with residential complex
Fixed Property Use Motor vehicle repair, paint shop
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Utility shaft
Level of Fire Origin Grade level to 9 feet above grade
Equipment Involved in Ignition No equipment involved
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Rubber
Form of Material Ignited Electrical wire, cable insulation
Ignition Factor Short circuit, ground fault
Construction Type Unprotected ordinary, not qualifying 5
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage No damage of this type
Detector Performance No detectors present
Sprinkler Performance No equipment present in room or space of fire origin
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 100-999 dollars
Occupancy Type Single or double occupancy
Occupancy Code MERCANTILE PROPERTIES, OFFICES; UNCLASSIFIED

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Rubber, excluding synthetic rubbers
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Unspecified short-circuit arc

Number of Stories With Damage


Story of Fire Origin 52

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Personal aircraft >= 12,500 lb. gross wt

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown
Sponsored