Incident Report – 10/16/2022 5034 Brookside Dr, Columbia, TN 38401
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On October 16, 2022, Columbia Fire & Rescue responded to a fire incident at 5034 Brookside Dr, Columbia, TN 38401, a 1-or-2 family dwelling.
The alarm was received at 12:38 PM, 15 suppression personnel arrived at 12:41 PM, and the last unit was cleared at 1:42 PM. The time to arrive was 3 minutes and the total incident time was 1 hour, 4 minutes.
The following actions were taken during the incident: extinguish, ventilate, and salvage and overhaul.
Sponsored
Location
| Type | Street address |
| Address | 5034 Brookside Dr, Columbia, TN 38401 |
| County | Maury County |
| State | TN |
| City | COLUMBIA |
| Zip Code | 38401 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Detector alerted occupants |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 3 minutes
Last unit cleared at
Alarm to last unit cleared: 1 hour, 4 minutes
Response
| Incident Type | Building fires |
| Department Station | 4 |
| Mutual Aid Given/Received | Automatic aid received |
| Resources Include Mutual Aid | No |
| District | W4 |
Personnel
| Support Personnel | 15 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Columbia Fire & Rescue |
| Department Type | Career |
| Address | 1000 S Garden St Columbia, TN 38401-3255 |
| Phone | (931) 560-1700 |
| Website | http://www.columbiatn.com/ |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Ventilate |
| Third Action Taken | Salvage & overhaul |
Losses *
| Property Loss | $5,000 |
| Contents Loss | $5,000 |
| Property Value | $252,000 |
| Contents Value | $85,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | TN_60313_10162022_0004300_0 |
| State | Tennessee |
| Fire Department ID | 60313 |
| Incident Date | 10/16/2022 |
| Incident Number | 0004300 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Electrical |
| Main Fire Cause | Electrical Malfunction |
| Priority Cause | Electrical Dist |
Ignition
| Area of Origin | Laundry area, wash house (laundry) |
| Heat Source | Undetermined |
| Item First Ignited | Electrical wire, cable insulation |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Equipment unattended |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Structural member or framing |
| Type Material Contributing Most To Spread | Sawn wood, including all finished lumber |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1348 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Smoke |
| Detector Power | Multiple detectors and power supplies |
| Detector Operation | Operated |
| Detector Effectiveness | No occupants |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Portable |
Sponsored