On January 18, 2020, Marble Falls Fire Rescue responded to a fire incident at 504 Avenue T, Marble Falls, TX 78654, a 1-or-2 family dwelling.

The alarm was received at 3:13 AM, 6 suppression personnel arrived at 3:16 AM, the incident was controlled at 3:19 AM, and the last unit was cleared at 4:12 AM. The time to arrive was 3 minutes, the time to control the incident was 3 minutes, and the total incident time was 59 minutes.

The following actions were taken during the incident: investigate fire out on arrival and salvage and overhaul.

Sponsored

Location


Type Street address
Address 504 Avenue T, Marble Falls, TX 78654
County Burnet County
State TX
City MARBLE FALLS
Zip Code 78654
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 3 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 3 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 59 minutes

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received Automatic aid received
Resources Include Mutual Aid No

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 0

Fire Department


Name Marble Falls Fire Rescue
Department Type Career
Address 700 Avenue N
Marble Falls, TX 78654-5528
Phone (830) 693-4060
Website https://marblefallstx.gov/169/Fire-Rescue

Actions Taken


First Action Taken Investigate fire out on arrival
Second Action Taken Salvage & overhaul

Losses *


Property Loss $2,000
Contents Loss $0
Property Value $125,000
Contents Value $0
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key TX_BP408_01182020_81_0
State Texas
Fire Department ID BP408
Incident Date 01/18/2020
Incident Number 81
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Equipment
Main Fire Cause Appliances
Priority Cause Air Conditioning

Ignition


Area of Origin Duct: hvac, cable, exhaust, heating, or AC
Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Confined To Origin Fire Spread was Confined to Object of Origin
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Electrical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 10000 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Failed to Operate
Detector Failure Reason Battery missing or disconnected

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary