Report Icon

Incident Report – 11/06/2022
536 Riverside Ln, Cayce, SC 29033

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On November 6, 2022, Cayce Fire Department responded to a fire incident at 536 Riverside Ln, Cayce, SC 29033, a 1-or-2 family dwelling.

The alarm was received at 9:19 PM, 4 suppression and 1 other personnel arrived at 9:23 PM, and the last unit was cleared at 9:52 PM. The time to arrive was 4 minutes and the total incident time was 33 minutes.

The following actions were taken during the incident: incident command and extinguish.

Sponsored

Location


Type Street address
Address 536 Riverside Ln, Cayce, SC 29033
County Lexington County
State SC
City CAYCE
Zip Code 29033
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 33 minutes

Response


Incident Type Building fires
Department Station ST1
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 4
EMS Personnel 0
Other Personnel 1

Fire Department


Name Cayce Fire Department
Department Type Mostly career
Address 2 Lavern Jumper Rd
Cayce, SC 29033
Phone (803) 794-0456
Website https://www.cityofcayce-sc.gov/publicsafety.php

Actions Taken


First Action Taken Incident command
Second Action Taken Extinguish

Metadata


Incident Key SC_32335_11062022_2201520_0
State South Carolina
Fire Department ID 32335
Incident Date 11/06/2022
Incident Number 2201520
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Appliances
Priority Cause Air Conditioning

Ignition


Area of Origin Attic: vacant, crawl space above top story, cupola
Heat Source Spark, ember or flame from operating equipment
Item First Ignited Pipe, duct, conduit, hose covering
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Undetermined
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Undetermined

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 4
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 1200 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Fire too small to operate

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored