On February 27, 2019, Torrington Fire Department responded to a fire incident at 59 Field St, Torrington, CT 06790, an industrial use, manufacturing/processing facility.
The alarm was received at 4:46 PM, 11 suppression and 4 other personnel arrived at 4:48 PM, and the last unit was cleared at 10:59 PM. The total incident time was 6 hours, 13 minutes.
The following action was taken during the incident: fire/other.
Sponsored
Location
| Type | Street address |
| Address | 59 Field St, Torrington, CT 06790 |
| County | Litchfield County |
| State | CT |
| City | TORRINGTON |
| Zip Code | 06790 |
| Mixed Use | Industrial use |
| Property Use | Manufacturing, processing |
| Hazardous Material Released | Special HazMat actions required or spill >= 55 gal |
Timeline
Alarm received at
Arrived at
Last unit cleared at
Alarm to last unit cleared: 6 hours, 13 minutes
Response
| Incident Type | Building fires |
| Department Station | STA |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Alarms | WO |
Personnel
| Support Personnel | 11 |
| EMS Personnel | 0 |
| Other Personnel | 4 |
Fire Department
| Name | Torrington Fire Department |
| Department Type | Mostly career |
| Address | 111 Water St Torrington, CT 06790-5321 |
| Phone | (860) 489-2255 |
| Website | https://www.torringtonct.org/fire-department |
Actions Taken
| First Action Taken | Fire, other |
Metadata
| Incident Key | CT_01210_02272019_1910610_0 |
| State | Connecticut |
| Fire Department ID | 01210 |
| Incident Date | 02/27/2019 |
| Incident Number | 1910610 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Natural |
| Main Fire Cause | Natural |
Ignition
| Area of Origin | Storage area, other |
| Heat Source | Chemical, natural heat source, other |
| Item First Ignited | Undetermined |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Abandoned or discarded materials or products |
On-Site Materials
| On-Site Material | Insulation |
Spread
| No Flame Spread/Same As First/Unknown | No |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | Other |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 40000 sqft |
| Number of Sprinklers Operating | 1 |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | Present |
| AES Type | Wet pipe sprinkler |
| AES Operation | Operated and Effective |
Suppression Factors
| Suppression Factor | Insulation combustible |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Sprinkler, water flow detection |
| Detector Power | Mechanical |
| Detector Operation | Operated |
| Detector Effectiveness | Alerted Occupants |