Incident Report – 12/26/2021 599 Pershing Ave, Lufkin, TX 75901
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Summary
On December 26, 2021, City of Lufkin Fire Department responded to a fire incident at 599 Pershing Ave, Lufkin, TX 75901, an industrial/utility/defense/agriculture/mining property.
The alarm was received on 12/26/2021 at 11:18 PM, 2 suppression personnel arrived on 12/26/2021 at 11:31 PM, the incident was controlled on 12/27/2021 at 1:30 AM, and the last unit was cleared on 12/27/2021 at 1:41 AM. The time to arrive was 13 minutes, the time to control the incident was 1 hour, 59 minutes, and the total incident time was 23 minutes.
The following action was taken during the incident: extinguish.
Location
| Type | Street address |
| Address | 599 Pershing Ave, Lufkin, TX 75901 |
| County | Angelina County |
| State | TX |
| City | Lufkin |
| Zip Code | 75901 |
| Property Use | Utility, defense, agriculture, mining, other |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 13 minutes
Incident controlled at
Alarm to incident controlled: 1 hour, 59 minutes
Last unit cleared at
Alarm to last unit cleared: 23 minutes
Response
| Incident Type | Fire, other |
| Department Station | 3 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 2 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | City of Lufkin Fire Department |
| Department Type | Career |
| Address | 111 S 3RD St Lufkin, TX 75901-3043 |
| Phone | (936) 633-0376 |
| Website | http://cityoflufkin.com/fd/index.htm |
Actions Taken
| First Action Taken | Extinguish |
Losses *
| Property Loss | $1,000 |
| Contents Loss | $0 |
| Property Value | $1,000 |
| Contents Value | $0 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | TX_AC608_12262021_004405_0 |
| State | Texas |
| Fire Department ID | AC608 |
| Incident Date | 12/26/2021 |
| Incident Number | 004405 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Ignition
| Area of Origin | Other |
| Heat Source | Undetermined |
| Item First Ignited | Undetermined |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Type of material first ignited, other |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Arc from faulty contact, broken conductor |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 0 |
Acres
| Less Than One Acre | Yes |