Incident Report – 04/30/1996 600 E Robinwood Dr, Robinson, IL 62454
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On April 30, 1996, Robinson Fire Protection District responded to a fire incident at 600 E Robinwood Dr, Robinson, IL 62454, a 24-hour care nursing home (four or more persons).
The alarm was received at 1:12 PM and 7 suppression personnel arrived at 1:14 PM.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 600 E Robinwood Dr, Robinson, IL 62454 |
| County | Crawford County |
| State | IL |
| City | Robinson |
| Zip Code | 62454 |
| Property Use | 24-hour care Nursing homes, 4 or more persons |
| Census Tract | 000000 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 0 |
| Alarms | 1 |
| District | 000 |
Personnel
| Support Personnel | 7 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Robinson Fire Protection District |
| Department Type | Mostly volunteer |
| Address | 400 S Jackson St ROBINSON, IL 62454-3412 |
| Phone | (618) 544-2955 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | IL_CK152_043096_960067_00 |
| State | Illinois |
| Fire Department ID | CK152 |
| Incident Date | 04/30/1996 |
| Incident Number | 960067 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Estimated Dollar Loss | 100 |
| Day of Week | Tuesday |
| Time In Service | 14:31 |
| Zip Code | 62454 |
| Method of Alarm | Radio |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | No complex |
| Fixed Property Use | Care of the aged with nursing staff |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Ceiling and roof assembly, concealed roof/ceiling space |
| Level of Fire Origin | 10 to 19 feet above grade |
| Number of Stories | 1 |
| Equipment Involved in Ignition | Fixed wiring |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Type of Material not classified above |
| Form of Material Ignited | Thermal, acoustical insulation within wall, partition, or floor/ceiling space |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Protected Wood Frame |
| Extent of Flame Damage | Confined to the object of origin |
| Extent of Smoke Damage | Confined to part of room or area of origin |
| Form of Material Generating Most Smoke | Type of Material not applicable |
| Detector Performance | Detector(s) not in the room or space of fire origin, and they did not operate |
| Avenue of Smoke Travel | Most Significant Avenue of Smoke Travel undetermined or not reported |
| Method of Extinguishment | Make-shift aids |
| Property Damage Classification | 100-999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | INSTITUTIONAL PROPERTY: UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Insulation within structural area |
| Type of Material | Type of material first ignited, other |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
Number of Stories With Damage
| Story of Fire Origin | 74 |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Armored vehicle |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |
Hazmat Report
Cause of Release
| Cause of Release | Container or containment failure |
Equipment Involved in Release
Equipment
| Equipment Brand | UNK |
| Equipment Model | UNK |
| Equipment Serial Number | UNK |
Legacy Fields
| Type of Situation Found | Structure fire |
| Complex | No complex |
| Fixed Property Use | Care of the aged with nursing staff |
| Mobile Property Type | Mobile Property Type not applicable |
| Area of Fire Origin | Ceiling and roof assembly, concealed roof/ceiling space |
| Equipment Involved in Ignition | Fixed wiring |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Type of Material not classified above |
| Form of Material Ignited | Thermal, acoustical insulation within wall, partition, or floor/ceiling space |
| Ignition Factor | Short circuit, ground fault |
| Dollar Loss | $100 |
Mobile Property
Description
| Model | N/A |
| License Plate | N/A |
Legacy Fields
| Make | N/A |
| Serial Number | N/A |
| Type of Situation Found | Structure fire |
| Complex | No complex |
| Fixed Property Use | Care of the aged with nursing staff |
| Mobile Property Type | Mobile Property Type not applicable |
| Area of Fire Origin | Ceiling and roof assembly, concealed roof/ceiling space |
| Equipment Involved in Ignition | Fixed wiring |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Type of Material not classified above |
| Form of Material Ignited | Thermal, acoustical insulation within wall, partition, or floor/ceiling space |
| Ignition Factor | Short circuit, ground fault |
| Time of Arrival | 13:12 |
| Dollar Loss | $100 |
Sponsored