On January 4, 2020, City of Spokane Fire Department responded to a fire incident at 6002 N Bridget St, Spokane, WA 99208, a 1-or-2 family dwelling.

The alarm was received at 10:12 AM, 13 suppression and 3 other personnel arrived at 10:18 AM, and the last unit was cleared at 10:27 AM. The time to arrive was 6 minutes and the total incident time was 15 minutes.

The following actions were taken during the incident: ventilate and investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 6002 N Bridget St, Spokane, WA 99208
County Spokane County
State WA
City Spokane
Zip Code 99208
Property Use 1 or 2 family dwelling

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 6 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 15 minutes

Response


Incident Type Building fires
Department Station 016
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift B
Alarms 1
District 022

Personnel


Support Personnel 13
EMS Personnel 0
Other Personnel 3

Fire Department


Name City of Spokane Fire Department
Department Type Career
Address 44 W Riverside Ave
Spokane, WA 99201-0189
Phone (509) 625-7000
Website https://my.spokanecity.org/fire/

Actions Taken


First Action Taken Ventilate
Second Action Taken Investigate fire out on arrival

Metadata


Incident Key WA_32M10_01042020_0000452_0
State Washington
Fire Department ID 32M10
Incident Date 01/04/2020
Incident Number 0000452
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Cooking
Priority Cause Cooking

Ignition


Area of Origin Cooking area, kitchen
Heat Source Heat from powered equipment, other
Item First Ignited Cooking materials, including edible materials
Confined To Origin Fire Spread was Confined to Object of Origin
Cause of Ignition Unintentional
Factor Contributing To Ignition Manual control failure

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 1
Building Length 40 ft
Building Width 60 ft

Number of Stories With Damage


Story of Fire Origin 1

Acres


Less Than One Acre No

Human Factors Contributing to Ignition


Human Factor Unattended or unsupervised person

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Power Electrical, other
Equipment Portability Portable