On July 20, 2022, Ottawa Fire Department responded to a fire incident at 601 Division St, Ottawa, IL 61350, a multifamily dwelling.

The alarm was received at 5:01 PM, 6 suppression, 1 EMS, and 1 other personnel arrived at 5:06 PM, and the last unit was cleared at 7:34 PM. The time to arrive was 5 minutes and the total incident time was 33 minutes.

The following actions were taken during the incident: extinguish and salvage and overhaul.

Sponsored

Location


Type Street address
Address 601 Division St, Ottawa, IL 61350
County LaSalle County
State IL
City Ottawa
Zip Code 61350
Property Use Multifamily dwellings

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 33 minutes

Response


Incident Type Building fires
Department Station 001
Mutual Aid Given/Received Mutual aid received
Resources Include Mutual Aid No
Shift 1
Alarms 1
District 7

Personnel


Support Personnel 6
EMS Personnel 1
Other Personnel 1

Fire Department


Name Ottawa Fire Department
Department Type Career
Address 301 W Lafayette St
Ottawa, IL 61350
Phone (815) 434-3785

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul

Losses *


Property Loss $20,000
Contents Loss $5,000
Property Value $250,000
Contents Value $15,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key IL_LB262_07202022_0002223_0
State Illinois
Fire Department ID LB262
Incident Date 07/20/2022
Incident Number 0002223
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Flame, Heat
Main Fire Cause Other Heat
Priority Cause Other open flame, spark

Ignition


Area of Origin Courtyard, patio, porch, terrace
Heat Source Heat from other open flame or smoking materials
Item First Ignited Structural member or framing
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Unintentional
Factor Contributing To Ignition Abandoned or discarded materials or products

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Structural component or finish, other
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential No
Number of Residential Units 6
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 3
Building Height: Stories Below Grade 1
Building Length 66 ft
Building Width 55 ft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Operated
Detector Effectiveness Alerted Occupants