Incident Report – 05/16/2016 602 Pine St, Winchester, KS 66097
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On May 16, 2016, Jefferson Fire District #10 responded to a fire incident at 602 Pine St, Winchester, KS 66097, a residential use, 1-or-2 family dwelling.
The alarm was received at 5:16 PM, 4 suppression personnel arrived at 5:20 PM, and the last unit was cleared at 6:37 PM. The time to arrive was 4 minutes and the total incident time was 1 hour, 21 minutes.
The following action was taken during the incident: control traffic.
Sponsored
Location
| Type | Street address |
| Address | 602 Pine St, Winchester, KS 66097 |
| County | Jefferson County |
| State | KS |
| City | Winchester |
| Zip Code | 66097 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Detector did not alert occupants |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 4 minutes
Last unit cleared at
Alarm to last unit cleared: 1 hour, 21 minutes
Response
| Incident Type | Outside equipment fire |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 4 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Jefferson Fire District #10 |
| Department Type | Volunteer |
| Address | 104 3rd St Winchester, KS 66097-4166 |
| Phone | (913) 306-6183 |
Actions Taken
| First Action Taken | Control traffic |
Metadata
| Incident Key | KS_JF409_05162016_0000067_0 |
| State | Kansas |
| Fire Department ID | JF409 |
| Incident Date | 05/16/2016 |
| Incident Number | 0000067 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Ignition
| Area of Origin | Highway, parking lot, street: on or near |
| Heat Source | Arcing |
| Item First Ignited | Transformer, including transformer fluids |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Round timber, including round posts, poles |
| Cause of Ignition | Act of nature |
| Factor Contributing To Ignition | Arc from faulty contact, broken conductor |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 0 |
Acres
| Less Than One Acre | No |
Suppression Factors
| Suppression Factor | Electrical power outage |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Stationary |
Sponsored