On October 15, 1998, Copperas Cove Fire Department responded to a fire incident at 605 N 11th St, Copperas Cove, TX 76522, a residential use, 1-or-2 family dwelling.

The alarm was received at 7:27 AM and 4 suppression personnel arrived at 7:27 AM.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 605 N 11th St, Copperas Cove, TX 76522
County Coryell County
State TX
City Copperas Cove
Zip Code 76522
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 010602
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift C
Alarms 1
District 002

Personnel


Support Personnel 4
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Copperas Cove Fire Department
Department Type Mostly career
Address 415 S Main St
Copperas Cove, TX 76522-2239
Phone (254) 547-2091
Website https://www.ci.copperas-cove.tx.us/pages/fire_department/fire_department.htm

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key TX_CX601_101598_000657_00
State Texas
Fire Department ID CX601
Incident Date 10/15/1998
Incident Number 000657
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Appliances

Legacy Fields


Estimated Dollar Loss 400
Day of Week Thursday
Zip Code 76522
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Garage, carport, vehicle storage area
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 0
Equipment Involved in Ignition Dryer
Form of Heat of Ignition Heat from properly operating electrical equipment
Type of Material Ignited Wig
Form of Material Ignited Wearing apparel not on a person
Ignition Factor Part failure, leak, break
Construction Type Protected Wood Frame
Extent of Flame Damage Confined to the object of origin
Extent of Smoke Damage No damage of this type
Form of Material Generating Most Smoke Form of Material undetermined or not reported
Detector Performance Detector(s) not in the room or space of fire origin, and they did not operate
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Type of Material undetermined or not reported
Avenue of Smoke Travel Most Significant Avenue of Smoke Travel undetermined or not reported
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 100-999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Radiated, conducted heat from operating equipment
Item First Ignited Wearing apparel not on a person
Type of Material Wig
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Leak or break

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 47

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Barge, petroleum balloon, towable water vessel

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown