On September 11, 1998, Joliet Fire Department responded to a fire incident at 621 E Benton St, Joliet, IL 60432, a residential use, 1-or-2 family dwelling.
The alarm was received at 12:43 PM and 15 suppression personnel arrived at 12:46 PM. The time to arrive was 3 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 621 E Benton St, Joliet, IL 60432 |
| County | Will County |
| State | IL |
| City | Joliet |
| Zip Code | 60432 |
| Mixed Use | Residential use |
| Property Use | 1 or 2 family dwelling |
| Census Tract | 882200 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 3 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | B |
| Alarms | 1 |
| District | 412 |
Personnel
| Support Personnel | 15 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Joliet Fire Department |
| Department Type | Career |
| Address | 101 E Clinton St Joliet, IL 60432-4137 |
| Phone | (815) 724-3500 |
| Website | https://www.joliet.gov/ |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | IL_WG221_091198_004324_00 |
| State | Illinois |
| Fire Department ID | WG221 |
| Incident Date | 09/11/1998 |
| Incident Number | 004324 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Unclassified elec malfunction |
Legacy Fields
| Estimated Dollar Loss | 2,500 |
| Day of Week | Friday |
| Time In Service | 13:50 |
| Zip Code | 60432 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 1 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | One-family dwelling: year-round use |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Exterior balcony, open porch |
| Level of Fire Origin | 10 to 19 feet above grade |
| Number of Stories | 2 |
| Equipment Involved in Ignition | Equipment Involved in Ignition undetermined or not reported |
| Form of Heat of Ignition | Unspecified short circuit arc |
| Type of Material Ignited | Sawn wood |
| Form of Material Ignited | Structural member, framing |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to the object of origin |
| Extent of Smoke Damage | Confined to the object of origin |
| Form of Material Generating Most Smoke | Type of Material not applicable |
| Detector Performance | Performance of Fire Detection Equipment undetermined or not reported |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Avenue of Smoke Travel | No significant avenue of smoke travel |
| Method of Extinguishment | Preconnected hose line(s) with water carried in apparatus tanks |
| Property Damage Classification | 1,000-9,999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | ONE- AND TWO-FAMILY DWELLING |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Structural member or framing |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Unspecified short-circuit arc |
Structure
| Number of Residential Units | 1 |
Number of Stories With Damage
| Story of Fire Origin | 72 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |