Incident Report – 01/16/1987 64 S Main, Oak City, UT 84649
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On January 16, 1987, Oak City Volunteer Fire Department responded to a fire incident at 64 S Main, Oak City, UT 84649, a storage facility.
The alarm was received at 3:50 AM and 10 suppression personnel arrived at 4:00 AM. The time to arrive was 10 minutes.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | 64 S Main, Oak City, UT 84649 |
| County | Millard County |
| State | UT |
| City | Oak City |
| Zip Code | 84649 |
| Property Use | Storage, other |
| Census Tract | 000000 |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 10 minutes
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Alarms | 1 |
Personnel
| Support Personnel | 10 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Oak City Volunteer Fire Department |
| Department Type | Volunteer |
| Address | 30 W Center St PO Box 51 Oak City, UT 84649 |
| Phone | (435) 846-3473 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | UT_27010_011687_000387_00 |
| State | Utah |
| Fire Department ID | 27010 |
| Incident Date | 01/16/1987 |
| Incident Number | 000387 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Unclassified equip. w/ other or unknown fuel source |
Legacy Fields
| Estimated Dollar Loss | 500 |
| Day of Week | Friday |
| Zip Code | 84649 |
| Method of Alarm | Coded signal municipal fire alarm system |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | No complex |
| Fixed Property Use | Storage Property; insufficient information available to classify further |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Storage Areas not classified above |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 1 |
| Equipment Involved in Ignition | No equipment involved |
| Form of Heat of Ignition | Heat from solid fueled equipment |
| Type of Material Ignited | Cotton, rayon, cotton fabric, finished goods |
| Form of Material Ignited | Mattress, pillow |
| Ignition Factor | Installed too close to combustibles |
| Construction Type | Undetermined or not reported |
| Extent of Flame Damage | Confined to structure of origin |
| Extent of Smoke Damage | Confined to structure or origin |
| Form of Material Generating Most Smoke | Type of Material not applicable |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Avenue of Smoke Travel | No significant avenue of smoke travel |
| Method of Extinguishment | Method of Extinguishment, Control undetermined or not reported |
| Property Damage Classification | 100-999 dollars |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | STORAGE PROPERTY: UNCLASSIFIED |
Fire Report
Ignition
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Mattress, pillow |
| Type of Material | Fabric, fiber, cotton, blends, rayon, wool |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Installation deficiency |
Number of Stories With Damage
| Story of Fire Origin | 49 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Water transport vessel, other |
Equipment
| Equipment Power | Solid fuel, other |
| Equipment Portability | Unknown |
Sponsored