On April 14, 1994, South Davis Fire District responded to a fire incident at 675 N Main St, Centerville, UT 84014, a residential use, 1-or-2 family dwelling.

The alarm was received at 5:20 PM and 8 suppression personnel arrived at 5:23 PM. The time to arrive was 3 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address 675 N Main St, Centerville, UT 84014
County Davis County
State UT
City Centerville
Zip Code 84014
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Census Tract 630000
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 3 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift C
Alarms 1
District 002

Personnel


Support Personnel 8
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name South Davis Fire District
Department Type Mostly volunteer
Address 385 N West Bountiful
Woods Cross, UT 84087
Phone (801) 936-6622

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key UT_11013_041494_940383_00
State Utah
Fire Department ID 11013
Incident Date 04/14/1994
Incident Number 940383
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Matches, Candles

Legacy Fields


Estimated Dollar Loss 500
Day of Week Thursday
Time In Service 18:10
Zip Code 84014
Method of Alarm Telephone tie-line to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Exterior roof surface
Level of Fire Origin Grade level to 9 feet above grade
Number of Stories 2
Equipment Involved in Ignition No equipment involved
Form of Heat of Ignition Match
Type of Material Ignited Grass, leaves, hay, straw
Form of Material Ignited Growing, living form
Ignition Factor Inadequate control of open fire
Construction Type Not classified above
Extent of Flame Damage Extended beyond structure of origin
Extent of Smoke Damage No damage of this type
Form of Material Generating Most Smoke Exterior trim, appurtenances
Detector Performance Detector(s) not in the room or space of fire origin, and they did not operate
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Grass, leaves, hay, straw
Avenue of Smoke Travel No significant avenue of smoke travel
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 100-999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Match
Item First Ignited Light vegetation - not crop, including grass
Type of Material Hay, straw
Cause of Ignition Unintentional
Factor Contributing To Ignition Outside/open fire for debris or waste disposal

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 77

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present