Incident Report – 10/21/2022 709 N Fm 1187 Apt 300, Aledo, TX 76008
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On October 21, 2022, Aledo Volunteer Fire Department responded to a fire incident at 709 N Fm 1187 Apt 300, Aledo, TX 76008, a personal service shop (including barber and beauty shops).
The alarm was received at 6:44 PM, 8 suppression personnel arrived at 6:50 PM, and the last unit was cleared at 7:02 PM. The time to arrive was 6 minutes and the total incident time was 18 minutes.
The following actions were taken during the incident: investigate fire out on arrival and remove hazard.
Sponsored
Location
| Type | Street address |
| Address | 709 N Fm 1187 Apt 300, Aledo, TX 76008 |
| County | Parker County |
| State | TX |
| City | Aledo |
| Zip Code | 76008 |
| Property Use | Personal service, including barber & beauty shops |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 6 minutes
Last unit cleared at
Alarm to last unit cleared: 18 minutes
Response
| Incident Type | Building fires |
| Department Station | 34 |
| Mutual Aid Given/Received | Automatic aid received |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 8 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Aledo Volunteer Fire Department |
| Department Type | Volunteer |
| Address | 215 Mesquite Trl Aledo, TX 76008 |
| Phone | (817) 523-7598 |
Actions Taken
| First Action Taken | Investigate fire out on arrival |
| Second Action Taken | Remove hazard |
Metadata
| Incident Key | TX_SY301_10212022_05342_0 |
| State | Texas |
| Fire Department ID | SY301 |
| Incident Date | 10/21/2022 |
| Incident Number | 05342 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Heating |
| Priority Cause | Heating |
Ignition
| Area of Origin | Heating room or area, water heater area |
| Heat Source | Arcing |
| Item First Ignited | Undetermined |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Undetermined |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Electrical failure, malfunction, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 1000 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Undetermined |
| Detector Operation | Undetermined |
Equipment
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Stationary |
Sponsored