Report Icon

Incident Report – 01/07/2017
713 Short St, Amarillo, TX 79102

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On January 7, 2017, Amarillo Fire Department responded to a fire incident at 713 Short St, Amarillo, TX 79102, a 1-or-2 family dwelling.

The alarm was received at 8:39 PM, 29 suppression personnel arrived at 8:44 PM, the incident was controlled at 9:03 PM, and the last unit was cleared at 10:29 PM. The time to arrive was 5 minutes, the time to control the incident was 19 minutes, and the total incident time was 1 hour, 50 minutes.

The following actions were taken during the incident: extinguish, salvage and overhaul, and incident command.

Sponsored

Location


Type Street address
Address 713 Short St, Amarillo, TX 79102
County Potter County
State TX
City Amarillo
Zip Code 79102
Property Use 1 or 2 family dwelling
Census Tract 115
Detector Alerted Occupants Detector alerted occupants
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 19 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 50 minutes

Response


Incident Type Building fires
Department Station 01
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift C
Alarms 1
District 01

Personnel


Support Personnel 29
EMS Personnel 0
Other Personnel 0

Fire Department


Name Amarillo Fire Department
Department Type Career
Address 310 S Van Buren St
Amarillo, TX 79101-1352
Phone (806) 378-9360
Website https://fire.amarillo.gov/

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul
Third Action Taken Incident command

Losses *


Property Loss $25,000
Contents Loss $10,000
Property Value $76,000
Contents Value $25,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key TX_TC701_01072017_0000520_0
State Texas
Fire Department ID TC701
Incident Date 01/07/2017
Incident Number 0000520
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Interior stairway or ramp
Heat Source Arcing
Item First Ignited Electrical wire, cable insulation
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Unintentional
Factor Contributing To Ignition Electrical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Structural component or finish, other
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential No
Number of Residential Units 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 1200 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 2
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Suppression Factors


Suppression Factor Attic undivided
Suppression Factor Ice

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored