Incident Report – 10/23/2020 715 E 1400 S, Orem, UT 84057
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On October 23, 2020, Orem Fire Department responded to a fire incident at 715 E 1400 S, Orem, UT 84057, a 1-or-2 family dwelling.
The alarm was received at 7:07 PM, 8 suppression, 6 EMS, and 2 other personnel arrived at 7:12 PM, and the last unit was cleared at 9:23 PM. The time to arrive was 5 minutes and the total incident time was 16 minutes.
The following actions were taken during the incident: fire/other, salvage and overhaul, and investigate.
Sponsored
Location
| Type | Street address |
| Address | 715 E 1400 S, Orem, UT 84057 |
| County | Utah County |
| State | UT |
| City | Orem |
| Zip Code | 84057 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Unknown |
| Hazardous Material Released | None |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 5 minutes
Last unit cleared at
Alarm to last unit cleared: 16 minutes
Response
| Incident Type | Building fires |
| Department Station | 1 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
Personnel
| Support Personnel | 8 |
| EMS Personnel | 6 |
| Other Personnel | 2 |
Fire Department
| Name | Orem Fire Department |
| Department Type | Career |
| Address | 95 E Center St Orem, UT 84057-4600 |
| Phone | (801) 229-7327 |
Actions Taken
| First Action Taken | Fire, other |
| Second Action Taken | Salvage & overhaul |
| Third Action Taken | Investigate |
Metadata
| Incident Key | UT_49010_10232020_2005190_0 |
| State | Utah |
| Fire Department ID | 49010 |
| Incident Date | 10/23/2020 |
| Incident Number | 2005190 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Appliances |
| Priority Cause | Appliances |
Ignition
| Area of Origin | Cooking area, kitchen |
| Heat Source | Heat from powered equipment, other |
| Item First Ignited | Cabinetry (including built-in) |
| Type of Material | Plywood |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Electrical failure, malfunction, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
Structure
| Not Residential | No |
| Number of Residential Units | 4 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | Vacant and secured |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 1 |
| Total Square Feet | 1200 sqft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 1 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Sponsored