On January 2, 2018, Berthoud Fire Protection District responded to a fire incident at 719 Marshall Place, Berthoud, CO 80513, a 1-or-2 family dwelling.

The alarm was received at 9:47 AM, 8 suppression personnel arrived at 9:52 AM, the incident was controlled at 10:06 AM, and the last unit was cleared at 11:02 AM. The time to arrive was 5 minutes, the time to control the incident was 14 minutes, and the total incident time was 1 hour, 15 minutes.

The following actions were taken during the incident: incident command, extinguish, and investigate.

Sponsored

Location


Type Street address
Address 719 Marshall Place, Berthoud, CO 80513
County Larimer County
State CO
City Berthoud
Zip Code 80513
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 14 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 15 minutes

Response


Incident Type Fires in structures other than in a building
Department Station 01
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 8
EMS Personnel 0
Other Personnel 0

Fire Department


Name Berthoud Fire Protection District
Department Type Mostly career
Address 275 Mountain Ave
Berthoud, CO 80513
Phone (970) 532-2264
Website https://www.berthoudfire.org/news.php

Actions Taken


First Action Taken Incident command
Second Action Taken Extinguish
Third Action Taken Investigate

Metadata


Incident Key CO_06905_01022018_6_0
State Colorado
Fire Department ID 06905
Incident Date 01/02/2018
Incident Number 6
Exposure Number 0
NFIRS Version 5.0

Fire Report

Ignition


Area of Origin Storage area, other
Heat Source Heat from powered equipment, other
Item First Ignited Storage supplies, other
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Electrical failure, malfunction, other

On-Site Materials


On-Site Material Livestock

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Fence, pole
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential Yes
Number of Buildings Involved 1
Structure Type Structure type, other
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 80 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Electrical, other
Equipment Portability Stationary