On May 18, 2020, Windsor Locks Fire Department responded to a fire incident at 8 Coolidge St, Windsor Locks, CT 06096, a 1-or-2 family dwelling.

The alarm was received at 11:16 AM, 25 suppression personnel arrived at 11:20 AM, the incident was controlled at 11:57 AM, and the last unit was cleared at 12:00 PM. The time to arrive was 4 minutes, the time to control the incident was 37 minutes, and the total incident time was 44 minutes.

The following actions were taken during the incident: extinguish, salvage and overhaul, and investigate.

Sponsored

Location


Type Street address
Address 8 Coolidge St, Windsor Locks, CT 06096
County Hartford County
State CT
City WINDSOR LOCKS
Zip Code 06096
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector did not alert occupants

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 4 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 37 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 44 minutes

Response


Incident Type Building fires
Department Station 01
Mutual Aid Given/Received Mutual aid received
Resources Include Mutual Aid No
Alarms 1

Personnel


Support Personnel 25
EMS Personnel 0
Other Personnel 0

Fire Department


Name Windsor Locks Fire Department
Department Type Volunteer
Address 2 Volunteer Dr
Windsor Locks, CT 06096
Phone (860) 627-1461
Website https://www.wlfd.com

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul
Third Action Taken Investigate

Losses *


Property Loss $1,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key CT_02290_05182020_0000146_0
State Connecticut
Fire Department ID 02290
Incident Date 05/18/2020
Incident Number 0000146
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Cause


General Cause Flame, Heat
Main Fire Cause Open Flame
Priority Cause Torches

Ignition


Area of Origin Wall assembly
Heat Source Flame/torch used for lighting
Item First Ignited Exterior wall covering or finish
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Unintentional
Factor Contributing To Ignition Equipment not being operated properly

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Building Length 60 ft
Building Width 20 ft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power LP gas or other heavier than air gas
Equipment Portability Portable