Incident Report – 03/26/2010 8 Gym Dr, Orono, ME 04469
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On March 26, 2010, Orono Fire Department responded to a fire incident at 8 Gym Dr, Orono, ME 04469, an office use, ballroom/gymnasium.
The following actions were taken during the incident: extinguish, salvage and overhaul, and search.
As a result of the incident, there was 1 fire service injury.
Sponsored
Location
| Type | Street address |
| Address | 8 Gym Dr, Orono, ME 04469 |
| County | Penobscot County |
| State | ME |
| City | Orono |
| Zip Code | 04469 |
| Mixed Use | Office use |
| Property Use | Ballroom, gymnasium |
| Detector Alerted Occupants | Detector alerted occupants |
Response
| Incident Type | Building fires |
| Department Station | 24 |
| Mutual Aid Given/Received | Automatic aid received |
| Resources Include Mutual Aid | No |
| Shift | A |
| Alarms | 4 |
| District | 25 |
Personnel
| Support Personnel | 5 |
| EMS Personnel | 0 |
| Other Personnel | 3 |
Fire Department
| Name | Orono Fire Department |
| Department Type | Career |
| Address | 63 Main St Orono, ME 04473-4001 |
| Phone | (207) 866-4000 |
| Website | https://www.orono.org/231/Fire-Department |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Salvage & overhaul |
| Third Action Taken | Search |
Injuries/Deaths
| Fire Service Injuries | 1 |
| Other Fire Injuries | 0 |
| Fire Service Deaths | 0 |
| Other Fire Deaths | 0 |
Losses *
| Property Loss | $0 |
| Contents Loss | $22,000 |
| Property Value | $29,000,000 |
| Contents Value | $14,500,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | ME_J3820_3262010_0000364_0 |
| State | Maine |
| Fire Department ID | J3820 |
| Incident Date | 03/26/2010 |
| Incident Number | 0000364 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| General Cause | Equipment |
| Main Fire Cause | Appliances |
| Priority Cause | Appliances |
Ignition
| Area of Origin | Laundry area, wash house (laundry) |
| Heat Source | Radiated, conducted heat from operating equipment |
| Item First Ignited | Dust, fiber, lint, including sawdust and excelsior |
| Confined To Origin | Fire Spread was Confined to Object of Origin |
| Type of Material | Fabric, fiber, cotton, blends, rayon, wool |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Failure to clean |
| Factor Contributing To Ignition | Operational deficiency, other |
Spread
| No Flame Spread/Same As First/Unknown | No |
Structure
| Not Residential | Yes |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 3 |
| Building Height: Stories Below Grade | 1 |
| Total Square Feet | 123198 sqft |
| Number of Sprinklers Operating | 0 |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Acres Burned | 0 |
| Less Than One Acre | Yes |
Automatic Extinguishing System
| AES Presence | Partial system present |
| AES Type | Wet pipe sprinkler |
| AES Operation | Fire too small to Operate |
Suppression Factors
| Suppression Factor | Ducts: vertical |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Combination smoke - heat |
| Detector Power | Hardwire Only |
| Detector Operation | Operated |
| Detector Effectiveness | Alerted Occupants |
Mobile Property Involved
| Mobile Property Year | 0 |
Equipment
| Equipment Brand | Amer |
| Equipment Model | AD-7 |
| Equipment Serial Number | 2308 |
| Equipment Year | 1987 |
| Equipment Power | Electrical line voltage (>= 50 volts) |
| Equipment Portability | Stationary |
Firefighter Casualty Report
Injured Person
| Gender | Male |
| Age | 26 |
Responses
| Prior Responses During Past 24 Hours | 1 |
Physical Condition
| Physical Condition | Rested |
Severity
| Severity | First aid only |
Taken To
| Taken To | Not transported |
Activity At Time Of Injury
| Activity At Time of Injury | Overhaul |
Injury
| Primary Apparent Symptom | Cut or laceration |
| Primary Area of Body Injured | Hand and fingers |
| Object Involved In Injury | Undetermined |
| Where Injury Occurred | Undetermined |
| Story of Injury | 0 |
| Specific Location | Undetermined |
| Protective Equipment Contributed to Injury | Yes |
Equipment Failures
Equipment Failure
| Item | Firefighter gloves with wristlets |
| Problem | Other problem |
Sponsored