On September 9, 1999, Troy Fire Department responded to a fire incident at 87 Duncan Dr, Troy, MI 480, a 1-or-2 family dwelling.

The following actions were taken during the incident: extinguish and salvage and overhaul.

Sponsored

Location


Type Street address
Address 87 Duncan Dr, Troy, MI 480
State MI
City TROY
Zip Code 480
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector did not alert occupants

Response


Incident Type Building fires
Department Station ST2
Mutual Aid Given/Received None
Resources Include Mutual Aid No
Shift A
Alarms 1
District F5

Fire Department


Name Troy Fire Department
Department Type Mostly volunteer
Address 500 W Big Beaver Rd
Troy, MI 48084-5254
Phone (248) 524-3419
Website https://www.troymi.gov/fire/

Actions Taken


First Action Taken Extinguish
Second Action Taken Salvage & overhaul

Losses *


Property Loss $20,000
Contents Loss $3,000
Property Value $200,000
Contents Value $75,000
  • Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.

Metadata


Incident Key MI_06340_9091999_0000961_0
State Michigan
Fire Department ID 06340
Incident Date 09/09/1999
Incident Number 0000961
Exposure Number 0
NFIRS Version 5.0

News Articles


Search Google

Fire Report

Ignition


Area of Origin Ceiling & floor assembly, crawl space b/t stories
Heat Source Arcing
Item First Ignited Structural member or framing
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Arc from faulty contact, broken conductor

Spread


No Flame Spread/Same As First/Unknown No
Item Contributing Most To Spread Structural member or framing
Type Material Contributing Most To Spread Sawn wood, including all finished lumber

Structure


Not Residential Yes
Number of Buildings Involved 0
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 1
Total Square Feet 1200 sqft
Number of Sprinklers Operating 0

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Fire too small to operate