Incident Report – 11/29/2022 900 Harcourt Rd, Mount Vernon, OH 43050
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On November 29, 2022, Mount Vernon Fire Department responded to a fire incident at 900 Harcourt Rd, Mount Vernon, OH 43050, a 1-or-2 family dwelling.
The alarm was received at 9:00 AM, 6 suppression, 2 EMS, and 2 other personnel arrived at 9:09 AM, and the last unit was cleared at 10:06 AM. The time to arrive was 9 minutes and the total incident time was 1 hour, 6 minutes.
The following actions were taken during the incident: investigate, incident command, and extinguish.
Sponsored
Location
| Type | Street address |
| Address | 900 Harcourt Rd, Mount Vernon, OH 43050 |
| County | Knox County |
| State | OH |
| City | MOUNT VERNON |
| Zip Code | 43050 |
| Property Use | 1 or 2 family dwelling |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 9 minutes
Last unit cleared at
Alarm to last unit cleared: 1 hour, 6 minutes
Response
| Incident Type | Fire in mobile home used as fixed residence |
| Department Station | 491 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | 2 |
| Alarms | 1 |
| District | 491 |
Personnel
| Support Personnel | 6 |
| EMS Personnel | 2 |
| Other Personnel | 2 |
Fire Department
| Name | Mount Vernon Fire Department |
| Department Type | Career |
| Address | 200 W Gambier St Mount Vernon, OH 43050-2424 |
| Phone | (740) 393-9515 |
Actions Taken
| First Action Taken | Investigate |
| Second Action Taken | Incident command |
| Third Action Taken | Extinguish |
Losses *
| Property Loss | $10,000 |
| Contents Loss | $1,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | OH_42017_11292022_0005754_0 |
| State | Ohio |
| Fire Department ID | 42017 |
| Incident Date | 11/29/2022 |
| Incident Number | 0005754 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
Fire Report
Cause
| Priority Cause | Unknown 1 |
Ignition
| Area of Origin | Wall assembly |
| Heat Source | Undetermined |
| Item First Ignited | Undetermined |
| Type of Material | Undetermined |
| Cause of Ignition | Cause under investigation |
| Factor Contributing To Ignition | Undetermined |
On-Site Materials
| On-Site Material | On-site materials, other |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Structural member or framing |
| Type Material Contributing Most To Spread | Fiberboard, particleboard, and hardboard |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Fixed portable or mobile structure |
| Structure Status | Idle, not routinely used |
| Building Height: Stories Above Grade | 1 |
| Building Height: Stories Below Grade | 0 |
| Building Length | 35 ft |
| Building Width | 12 ft |
Number of Stories With Damage
| Story of Fire Origin | 1 |
| Number of Stories with Damage: Minor | 1 |
| Number of Stories with Damage: Significant | 0 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
| Detector Failure Reason | Hardwired power failure, shut-off or disconnect |