Incident Report – 05/25/2016 9130 Sage Loop Ct, Temple, TX 76504
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On May 25, 2016, Temple Fire & Rescue responded to a fire incident at 9130 Sage Loop Ct, Temple, TX 76504, a 1-or-2 family dwelling.
The alarm was received at 3:18 AM, 24 suppression personnel arrived at 3:26 AM, and the last unit was cleared at 9:26 AM. The time to arrive was 8 minutes and the total incident time was 6 hours, 8 minutes.
The following actions were taken during the incident: extinguish, salvage and overhaul, and search.
As a result of the incident, there was 1 fire service injury.
Sponsored
Location
| Type | Street address |
| Address | 9130 Sage Loop Ct, Temple, TX 76504 |
| County | Bell County |
| State | TX |
| City | TEMPLE |
| Zip Code | 76504 |
| Property Use | 1 or 2 family dwelling |
| Detector Alerted Occupants | Detector alerted occupants |
Timeline
Alarm received at
Arrived at
Alarm to arrival: 8 minutes
Last unit cleared at
Alarm to last unit cleared: 6 hours, 8 minutes
Response
| Incident Type | Building fires |
| Department Station | TF7 |
| Mutual Aid Given/Received | None |
| Resources Include Mutual Aid | No |
| Shift | C |
| Alarms | 1 |
| District | 7 |
Personnel
| Support Personnel | 24 |
| EMS Personnel | 0 |
| Other Personnel | 0 |
Fire Department
| Name | Temple Fire & Rescue |
| Department Type | Career |
| Address | 210 N 3RD St Temple, TX 76501-3102 |
| Phone | (254) 298-5682 |
| Website | https://www.templetx.gov/index.aspx?nid=123 |
Actions Taken
| First Action Taken | Extinguish |
| Second Action Taken | Salvage & overhaul |
| Third Action Taken | Search |
Injuries/Deaths
| Fire Service Injuries | 1 |
| Fire Service Deaths | 0 |
Losses *
| Property Loss | $100,000 |
| Contents Loss | $40,000 |
| Property Value | $100,000 |
| Contents Value | $40,000 |
- Losses are approximate and are considered less reliable than other data elements per NFIRS fire data analysis guidelines.
Metadata
| Incident Key | TX_AV612_05252016_1605364_0 |
| State | Texas |
| Fire Department ID | AV612 |
| Incident Date | 05/25/2016 |
| Incident Number | 1605364 |
| Exposure Number | 0 |
| NFIRS Version | 5.0 |
News Articles
Search Google
EMS Report
Patient Description
| Provider Impression/Assessment | None/no patient or refused treatment |
| Patient Age | 38 |
| Patient Gender | Male |
| Patient Race | White |
| Patient Ethnicity | Other |
Timeline
Arrived at
Injury Types
| Cause of Illness/Injury | Fire and flames |
Procedures Used
| Procedure Used | No treatment |
Fire Report
Ignition
| Area of Origin | Attic: vacant, crawl space above top story, cupola |
| Heat Source | Undetermined |
| Item First Ignited | Structural member or framing |
| Type of Material | Sawn wood, including all finished lumber |
| Cause of Ignition | Unintentional |
| Factor Contributing To Ignition | Undetermined |
Spread
| No Flame Spread/Same As First/Unknown | Yes |
| Item Contributing Most To Spread | Undetermined |
Structure
| Not Residential | No |
| Number of Residential Units | 1 |
| Number of Buildings Involved | 1 |
| Structure Type | Enclosed building |
| Structure Status | In normal use |
| Building Height: Stories Above Grade | 2 |
| Building Height: Stories Below Grade | 0 |
| Total Square Feet | 3000 sqft |
Number of Stories With Damage
| Story of Fire Origin | 2 |
| Number of Stories with Damage: Minor | 0 |
| Number of Stories with Damage: Significant | 1 |
| Number of Stories with Damage: Heavy | 0 |
| Number of Stories with Damage: Extreme | 0 |
Acres
| Less Than One Acre | No |
Automatic Extinguishing System
| AES Presence | None Present |
Suppression Factors
| Suppression Factor | Roof assembly combustible |
| Suppression Factor | Attic undivided |
Detector
| Detector Presence | Detectors Present |
| Detector Type | Other |
| Detector Power | Hardwire with battery |
| Detector Operation | Operated |
| Detector Effectiveness | Alerted Occupants |
Equipment
| Equipment Power | Undetermined |
| Equipment Portability | Stationary |
Firefighter Casualty Report
Injured Person
| Gender | Male |
| Age | 38 |
Injury Date and Time
| Injury Date and Time | 05/25/2016 3:26 AM |
Responses
| Prior Responses During Past 24 Hours | 7 |
Physical Condition
| Physical Condition | Rested |
Severity
| Severity | Treated by physician, not a lost-time injury |
Taken To
| Taken To | Doctor's office |
Activity At Time Of Injury
| Activity At Time of Injury | Extinguishing fire/neutralizing incident, other |
Injury
| Primary Apparent Symptom | Burn: scald |
| Primary Area of Body Injured | Arm-lower, not including elbow or wrist |
| Object Involved In Injury | Steam |
| Where Injury Occurred | At scene, in structure |
| Story of Injury | 2 |
| Specific Location | In structure, excluding attic, roof, or wall |
| Vehicle Type | Non-fire department vehicle (includes POV) |
| Protective Equipment Contributed to Injury | No |
Sponsored