Report Icon

Incident Report – 04/18/2020
932 Zamora Rd, Leander, TX 78641

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On April 18, 2020, Leander Fire Department responded to a fire incident at 932 Zamora Rd, Leander, TX 78641, a 1-or-2 family dwelling.

The alarm was received at 4:27 PM, 14 suppression personnel arrived at 4:37 PM, and the last unit was cleared at 6:54 PM. The time to arrive was 10 minutes and the total incident time was 27 minutes.

The following action was taken during the incident: investigate fire out on arrival.

Sponsored

Location


Type Street address
Address 932 Zamora Rd, Leander, TX 78641
County Williamson County
State TX
City Leander
Zip Code 78641
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Detector alerted occupants
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 10 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 27 minutes

Response


Incident Type Building fires
Department Station 4
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 14
EMS Personnel 0
Other Personnel 0

Fire Department


Name Leander Fire Department
Department Type Mostly career
Address 101 E Sonny Dr
Leander, TX 78641
Phone (512) 528-2848
Website https://www.leandertx.gov/fire

Actions Taken


First Action Taken Investigate fire out on arrival

Metadata


Incident Key TX_XV308_04182020_1023_0
State Texas
Fire Department ID XV308
Incident Date 04/18/2020
Incident Number 1023
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Appliances
Priority Cause Appliances

Ignition


Area of Origin Ceiling & floor assembly, crawl space b/t stories
Heat Source Arcing
Item First Ignited Interior ceiling cover or finish
Type of Material Plywood
Cause of Ignition Unintentional
Factor Contributing To Ignition Unspecified short-circuit arc

Spread


No Flame Spread/Same As First/Unknown Yes
Item Contributing Most To Spread Structural member or framing
Type Material Contributing Most To Spread LP gas

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 2
Building Height: Stories Below Grade 0
Total Square Feet 2800 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Hardwire with battery
Detector Operation Operated
Detector Effectiveness Alerted Occupants

Equipment


Equipment Power Electrical line voltage (>= 50 volts)
Equipment Portability Stationary
Sponsored