On July 28, 2022, Montello Fire Department responded to a fire incident at 94 3rd St, Montello, WI 53949, an outbuilding/shed.

The alarm was received at 3:54 PM, 6 suppression personnel arrived at 4:04 PM, the incident was controlled at 4:15 PM, and the last unit was cleared at 4:21 PM. The time to arrive was 10 minutes, the time to control the incident was 11 minutes, and the total incident time was 27 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Type Street address
Address 94 3rd St, Montello, WI 53949
County Marquette County
State WI
City Montello
Zip Code 53949
Property Use Outbuilding or shed
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 10 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 11 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 27 minutes

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 6
EMS Personnel 0
Other Personnel 0

Fire Department


Name Montello Fire Department
Department Type Volunteer
Address 20 Underwood Ave
PO Box 39
Montello, WI 53949-0039
Phone (608) 297-9237

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key WI_39020_07282022_220712_0
State Wisconsin
Fire Department ID 39020
Incident Date 07/28/2022
Incident Number 220712
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Flame, Heat
Main Fire Cause Smoking

Ignition


Area of Origin Outside area, other
Heat Source Cigarette
Item First Ignited Undetermined
Type of Material Undetermined
Cause of Ignition Unintentional
Factor Contributing To Ignition Undetermined

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential Yes
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present