Report Icon

Incident Report – 11/18/2020
94 Cottage Rd, Madison, CT 06443

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On November 18, 2020, Madison Hose Company #1 responded to a fire incident at 94 Cottage Rd, Madison, CT 06443, a non-mixed use, 1-or-2 family dwelling.

The alarm was received at 2:25 AM, 14 suppression personnel arrived at 2:37 AM, and the last unit was cleared at 3:19 AM. The time to arrive was 12 minutes and the total incident time was 54 minutes.

The following actions were taken during the incident: investigate fire out on arrival and salvage and overhaul.

Sponsored

Location


Type Street address
Address 94 Cottage Rd, Madison, CT 06443
County New Haven County
State CT
City MADISON
Zip Code 06443
Mixed Use Not mixed use
Property Use 1 or 2 family dwelling
Census Tract 194100
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 12 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 54 minutes

Response


Incident Type Building fires
Department Station MHC
Mutual Aid Given/Received Automatic aid received
Resources Include Mutual Aid No
Alarms 1
District 1

Personnel


Support Personnel 14
EMS Personnel 0
Other Personnel 0

Fire Department


Name Madison Hose Company #1
Department Type Volunteer
Address PO Box 573
Madison, CT 06443
Phone (203) 245-2772

Actions Taken


First Action Taken Investigate fire out on arrival
Second Action Taken Salvage & overhaul

Metadata


Incident Key CT_06110_11182020_0001025_0
State Connecticut
Fire Department ID 06110
Incident Date 11/18/2020
Incident Number 0001025
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Electrical
Main Fire Cause Electrical Malfunction
Priority Cause Unclassified elec malfunction

Ignition


Area of Origin Wall assembly
Heat Source Arcing
Item First Ignited Appliance housing or casing
Confined To Origin Fire Spread was Confined to Object of Origin
Type of Material Plastic
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Unspecified short-circuit arc

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 2
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status In normal use
Building Height: Stories Above Grade 3
Building Height: Stories Below Grade 1
Total Square Feet 744 sqft

Number of Stories With Damage


Story of Fire Origin 2
Number of Stories with Damage: Minor 1
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 0

Acres


Acres Burned 0
Less Than One Acre No

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence Detectors Present
Detector Type Smoke
Detector Power Battery Only
Detector Operation Fire too small to operate