Report Icon

Incident Report – 03/06/1988
Box 52 Rr 1 3rd Maple, Verdon, NE 68457

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On March 6, 1988, Verdon Volunteer Fire Department responded to a fire incident at Box 52 Rr 1 3rd Maple, Verdon, NE 68457, a residential use, 1-or-2 family dwelling.

The alarm was received at 8:25 AM and 15 suppression personnel arrived at 8:30 AM. The time to arrive was 5 minutes.

The following action was taken during the incident: extinguish.

Sponsored

Location


Address Box 52 Rr 1 3rd Maple, Verdon, NE 68457
County Richardson County
State NE
City Verdon
Zip Code 68457
Mixed Use Residential use
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 5 minutes

Response


Incident Type Structure fire, other
Mutual Aid Given/Received None
Shift 0
Alarms 0
District 000

Personnel


Support Personnel 15
EMS Personnel Unknown
Other Personnel Unknown

Fire Department


Name Verdon Volunteer Fire Department
Department Type Volunteer
Address 308 Main St
Verdon, NE 68457
Phone (402) 883-2833

Actions Taken


First Action Taken Extinguish

Metadata


Incident Key NE_19009_030688_880002_00
State Nebraska
Fire Department ID 19009
Incident Date 03/06/1988
Incident Number 880002
Exposure Number 00
NFIRS Version 4.1
Priority Cause Code Electrical Dist

Legacy Fields


Estimated Dollar Loss 13,000
Day of Week Sunday
Time In Service 11:32
Zip Code 68457
Method of Alarm Telephone direct to fire department
Type of Situation Found Structure fire
Type Action Taken Extinguishment
Number of Aerial Apparatus 0
Complex Dwelling complex (one-and two-family)
Fixed Property Use One-family dwelling: year-round use
Mobile Property type Mobile Property Type not applicable
Area of Fire Origin Ceiling and roof assembly, concealed roof/ceiling space
Level of Fire Origin 20 to 29 feet above grade
Number of Stories 2
Equipment Involved in Ignition Fixed wiring
Form of Heat of Ignition Unspecified short circuit arc
Type of Material Ignited Sawn wood
Form of Material Ignited Structural member, framing
Ignition Factor Short circuit, ground fault
Construction Type Unprotected wood frame not qualifying for 7
Extent of Flame Damage Confined to part of room or area of origin
Extent of Smoke Damage Extended beyond structure of origin
Form of Material Generating Most Smoke Structural member, framing
Detector Performance Detector(s) not in the room or space of fire origin, and they did not operate
Sprinkler Performance No equipment present in room or space of fire origin
Type of Material Generating Most Smoke Sawn wood
Avenue of Smoke Travel Opening in construction
Method of Extinguishment Preconnected hose line(s) with water carried in apparatus tanks
Property Damage Classification 10,000-24,999 dollars
Occupancy Type Single or double occupancy
Occupancy Code ONE- AND TWO-FAMILY DWELLING

Fire Report

Ignition


Heat Source Arcing
Item First Ignited Structural member or framing
Type of Material Sawn wood, including all finished lumber
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Unspecified short-circuit arc

Structure


Number of Residential Units 1

Number of Stories With Damage


Story of Fire Origin 74

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Mobile Property Involved


Mobile Property Type Armored vehicle

Equipment


Equipment Power Electrical, other
Equipment Portability Unknown
Sponsored