Incident Report – 03/06/1995 Charles and Orms, Bradford, RI 02808
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On March 6, 1995, Providence Fire Department responded to a fire incident at Charles and Orms, Bradford, RI 02808, a residential use, hotel/motel (commercial).
The alarm was received at 6:10 PM and 20 suppression personnel arrived at 6:12 PM.
The following action was taken during the incident: investigate.
Sponsored
Location
| Address | Charles and Orms, Bradford, RI 02808 |
| County | Washington County |
| State | RI |
| City | Bradford |
| Zip Code | 02808 |
| Mixed Use | Residential use |
| Property Use | Hotel/motel, commercial |
| Census Tract | 002600 |
| Detector Alerted Occupants | Detector alerted occupants |
Timeline
Alarm received at
Arrived at
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Shift | 2 |
| Alarms | 1 |
| District | 002 |
Personnel
| Support Personnel | 20 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Providence Fire Department |
| Department Type | Career |
| Address | 325 Washington St Providence, RI 02903 |
| Phone | (401) 243-6060 |
Actions Taken
| First Action Taken | Investigate |
Metadata
| Incident Key | RI_02800_030695_006383_00 |
| State | Rhode Island |
| Fire Department ID | 02800 |
| Incident Date | 03/06/1995 |
| Incident Number | 006383 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Unknown 2 |
Legacy Fields
| Estimated Dollar Loss | 0 |
| Day of Week | Monday |
| Time In Service | 18:44 |
| Zip Code | 02808 |
| Method of Alarm | Method of Alarm from the Public undetermined or not reported |
| Type of Situation Found | Structure fire |
| Type Action Taken | Investigation only |
| Number of Aerial Apparatus | 2 |
| Complex | Hotel complex |
| Fixed Property Use | 20 to 99 units: year-round use |
| Area of Fire Origin | Machinery room, area |
| Level of Fire Origin | Grade level to 9 feet above grade |
| Number of Stories | 3 |
| Equipment Involved in Ignition | Other Object, not classified above |
| Form of Heat of Ignition | Form of Heat of Ignition undetermined or not reported |
| Type of Material Ignited | Type of Material undetermined or not reported |
| Form of Material Ignited | Form of Material undetermined or not reported |
| Ignition Factor | Ignition Factor undetermined or not reported |
| Construction Type | Fire resistive |
| Extent of Flame Damage | Extent of Flame Damage undetermined or not reported |
| Extent of Smoke Damage | Confined to part of room or area of origin |
| Form of Material Generating Most Smoke | Form of Material undetermined or not reported |
| Detector Performance | Detector(s) in the room or space of fire origin, and they operated |
| Sprinkler Performance | Equipment present but fire too small to require operation |
| Type of Material Generating Most Smoke | Type of Material undetermined or not reported |
| Avenue of Smoke Travel | Corridor |
| Method of Extinguishment | Portable extinguisher |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | HOTELS, MOTELS, INNS, LODGES |
Fire Report
Ignition
| Heat Source | Undetermined |
| Item First Ignited | Undetermined |
| Type of Material | Undetermined |
| Cause of Ignition | Cause undetermined after investigation |
| Factor Contributing To Ignition | Undetermined |
Structure
| Number of Residential Units | 50 |
| Number of Sprinklers Operating | 0 |
Number of Stories With Damage
| Story of Fire Origin | 61 |
Automatic Extinguishing System
| AES Presence | Present |
| AES Type | Undetermined |
| AES Operation | Fire too small to Operate |
Detector
| Detector Presence | Detectors Present |
| Detector Operation | Operated |
| Detector Effectiveness | Undetermined |
Mobile Property Involved
| Mobile Property Type | Construction vehicles |
Sponsored