Report Icon

Incident Report – 12/29/2022
Chatterton and Sharp St, Saratoga, WY 82331

Download Full Report

Download Full Report
Price
$4.99
FeatureCheck
Includes Owner Information
FeatureCheck
Formatted for Commercial, Legal, and other Professional Usage
FeatureCheck
Download as PDF
Money-back Guarantee.

Summary


On December 29, 2022, Saratoga Volunteer Fire Department responded to a fire incident at Chatterton and Sharp St, Saratoga, WY 82331, a 1-or-2 family dwelling.

The alarm was received at 9:25 AM, 2 suppression personnel arrived at 9:40 AM, the incident was controlled at 9:55 AM, and the last unit was cleared at 10:30 AM. The time to arrive was 15 minutes, the time to control the incident was 15 minutes, and the total incident time was 1 hour, 5 minutes.

The following action was taken during the incident: salvage and overhaul.

Sponsored

Location


Type Intersection
Address Chatterton and Sharp St, Saratoga, WY 82331
County Carbon County
State WY
City Saratoga
Zip Code 82331
Property Use 1 or 2 family dwelling
Detector Alerted Occupants Unknown
Hazardous Material Released None

Timeline


  • Alarm

    Alarm received at

  • Arrived

    Arrived at

    Alarm to arrival: 15 minutes

  • Incident Controlled

    Incident controlled at

    Alarm to incident controlled: 15 minutes

  • Last Unit Cleared

    Last unit cleared at

    Alarm to last unit cleared: 1 hour, 5 minutes

Response


Incident Type Building fires
Department Station 1
Mutual Aid Given/Received None
Resources Include Mutual Aid No

Personnel


Support Personnel 2
EMS Personnel 0
Other Personnel 0

Fire Department


Name Saratoga Volunteer Fire Department
Department Type Volunteer
Address 210 E Spring
PO Box 96
Saratoga, WY 82331-0096
Phone (307) 326-5333

Actions Taken


First Action Taken Salvage & overhaul

Metadata


Incident Key WY_07527_12292022_064_0
State Wyoming
Fire Department ID 07527
Incident Date 12/29/2022
Incident Number 064
Exposure Number 0
NFIRS Version 5.0

Fire Report

Cause


General Cause Equipment
Main Fire Cause Heating
Priority Cause Heating

Ignition


Area of Origin Heating room or area, water heater area
Heat Source Heat from powered equipment, other
Item First Ignited Structural component or finish, other
Type of Material Fiberboard, particleboard, and hardboard
Cause of Ignition Failure of equipment or heat source
Factor Contributing To Ignition Mechanical failure, malfunction, other

Spread


No Flame Spread/Same As First/Unknown Yes

Structure


Not Residential No
Number of Residential Units 1
Number of Buildings Involved 1
Structure Type Enclosed building
Structure Status Idle, not routinely used
Building Height: Stories Above Grade 1
Building Height: Stories Below Grade 0
Total Square Feet 700 sqft

Number of Stories With Damage


Story of Fire Origin 1
Number of Stories with Damage: Minor 0
Number of Stories with Damage: Significant 0
Number of Stories with Damage: Heavy 0
Number of Stories with Damage: Extreme 1

Acres


Less Than One Acre Yes

Automatic Extinguishing System


AES Presence None Present

Detector


Detector Presence None Present

Equipment


Equipment Power Natural gas or other lighter than air gas
Equipment Portability Stationary
Sponsored