Incident Report – 06/05/1994 Co Rd 206, Haskell, TX 79521
Download Full Report
- Download Full Report
- Price
- $4.99
- Feature
- Includes Owner Information
- Feature
- Formatted for Commercial, Legal, and other Professional Usage
- Feature
- Download as PDF
Money-back Guarantee.
Summary
On June 5, 1994, Haskell Volunteer Fire Department responded to a fire incident at Co Rd 206, Haskell, TX 79521, a residential use property.
The alarm was received at 6:15 PM and 11 suppression personnel arrived at 6:15 PM.
The following action was taken during the incident: extinguish.
Sponsored
Location
| Address | Co Rd 206, Haskell, TX 79521 |
| County | Haskell County |
| State | TX |
| City | Haskell |
| Zip Code | 79521 |
| Mixed Use | Residential use |
| Property Use | Undetermined |
| Detector Alerted Occupants | Unknown |
Timeline
Alarm received at
Arrived at
Response
| Incident Type | Structure fire, other |
| Mutual Aid Given/Received | None |
| Alarms | 1 |
Personnel
| Support Personnel | 11 |
| EMS Personnel | Unknown |
| Other Personnel | Unknown |
Fire Department
| Name | Haskell Volunteer Fire Department |
| Department Type | Volunteer |
| Address | 301 N 1ST St Haskell, TX 79521-5906 |
| Phone | (940) 864-3052 |
Actions Taken
| First Action Taken | Extinguish |
Metadata
| Incident Key | TX_KD401_060594_000018_00 |
| State | Texas |
| Fire Department ID | KD401 |
| Incident Date | 06/05/1994 |
| Incident Number | 000018 |
| Exposure Number | 00 |
| NFIRS Version | 4.1 |
| Priority Cause Code | Electrical Dist |
Legacy Fields
| Estimated Dollar Loss | 0 |
| Day of Week | Sunday |
| Time In Service | 19:30 |
| Zip Code | 79521 |
| Method of Alarm | Telephone direct to fire department |
| Type of Situation Found | Structure fire |
| Type Action Taken | Extinguishment |
| Number of Aerial Apparatus | 0 |
| Complex | Dwelling complex (one-and two-family) |
| Fixed Property Use | Vacant property |
| Mobile Property type | Mobile Property Type not applicable |
| Area of Fire Origin | Exterior wall surface |
| Level of Fire Origin | 10 to 19 feet above grade |
| Number of Stories | 0 |
| Equipment Involved in Ignition | Fixed wiring |
| Form of Heat of Ignition | Short circuit arc from defective, worn insulation |
| Type of Material Ignited | Hardboard, plywood |
| Form of Material Ignited | Exterior sidewall covering, surface, finish |
| Ignition Factor | Short circuit, ground fault |
| Construction Type | Unprotected wood frame not qualifying for 7 |
| Extent of Flame Damage | Confined to structure of origin |
| Extent of Smoke Damage | Confined to structure or origin |
| Form of Material Generating Most Smoke | Form of Material undetermined or not reported |
| Detector Performance | No detectors present |
| Sprinkler Performance | No equipment present in room or space of fire origin |
| Type of Material Generating Most Smoke | Wood shavings |
| Avenue of Smoke Travel | No significant avenue of smoke travel |
| Method of Extinguishment | Preconnected hose line(s) with water carried in apparatus tanks |
| Property Damage Classification | Undertermined |
| Occupancy Type | Single or double occupancy |
| Occupancy Code | CONSTRUCTION, UNOCCUPIED PROPERTY |
Fire Report
Ignition
| Heat Source | Arcing |
| Item First Ignited | Exterior wall covering or finish |
| Type of Material | Plywood |
| Cause of Ignition | Failure of equipment or heat source |
| Factor Contributing To Ignition | Short circuit arc from defective, worn insulation |
Structure
| Structure Status | Vacant and unsecured |
Number of Stories With Damage
| Story of Fire Origin | 76 |
Automatic Extinguishing System
| AES Presence | None Present |
Detector
| Detector Presence | None Present |
Mobile Property Involved
| Mobile Property Type | Aerial tramway vehicle |
Equipment
| Equipment Power | Electrical, other |
| Equipment Portability | Unknown |